background image

Installation Overview 

Read all instructions before attempting to assemble or install the Lift. 

Anchor Location 

It is recommended that the Summit be installed in or near the shallow end of the pool with 
sufficient deck space and operational area in the pool as shown in Figure 1. For reasons of 
safety and ADA guidelines, the lift must be installed in a location that is clear from obstacles and 
other hazards.  

NOTE:

 Do not locate the lift in a corner or directly adjacent to pool ladders/handrails or grab rails 

that could interfere with the rotation of the lift. Do not place the lift where it may be cumbersome 
or hazardous to any pool users. 

 

 

Figure 1 

Because the lift can be stopped at any position during lowering, there is no minimum pool depth 
requirement for the Summit. However, to comply with ADA guidelines, the Summit must be 
installed at a pool depth no greater than 48-inches and the seat should submerge to a minimum 
depth of 18” below the surface of the water. There must be at least 6” from the center of each 
anchor to the nearest joint, crack, curb or similar concrete structure to ensure the strength of the 
concrete.   

In addition, all installations should be in accordance with the ADA guidelines (ADA guidelines 
are available at the websit

www.access-board.gov

).   

Anchor Installation 

1.  Mark the location of each anchor on the deck and use a 1” diameter concrete drill bit to drill 

a 2 1/4” deep hole at each location.  Make sure to drill straight down.  

2.  Clean all debris from hole and place the expansion anchor into the hole. Tap the anchor into 

the hole until the top of the anchor is flush with the deck. 

800.791.8056 

▪ www.spectrumproducts.com 

Summary of Contents for Spectrum Aquatics Summit WP 400

Page 1: ...Summit WP 400 Part Number 42440 7100 Spectrum Lane Missoula MT 59808 800 791 8056 www spectrumproducts com 42440 Man Rev A ...

Page 2: ...llet Before accepting the shipment from the carrier inspect for visible damage and match the contents with those listed below Spectrum is not responsible for lost or damaged freight The Pallet will contain all structural components and hardware The following is a list of the components included with your shipment from Spectrum Use Components and Hardware Figure page 2 as a reference to identify ea...

Page 3: ...Components and Hardware 2 800 791 8056 www spectrumproducts com ...

Page 4: ... no minimum pool depth requirement for the Summit However to comply with ADA guidelines the Summit must be installed at a pool depth no greater than 48 inches and the seat should submerge to a minimum depth of 18 below the surface of the water There must be at least 6 from the center of each anchor to the nearest joint crack curb or similar concrete structure to ensure the strength of the concrete...

Page 5: ...using a 3 8 x 3 Button Head screw two 3 8 flat washers one 3 8 lock washer and a 3 8 acorn nut 2 Attach the Rotationally molded Seat halves to the Seat arm using eight 5 16 x 1 Button head screws 5 16 washers and 5 16 lock washers Make sure to attach the seatbelt using the rear holes on the bottom seat half 3 Connect footrest using one button head socket screw 1 4 x 1 2 and one 1 4 lock washer 4 P...

Page 6: ...w check valve is required Lift Preparation 1 Turn the control valve to the intermediate stop position and attach the water supply hose to the valve Turn the water supply on 2 With no weight on the chair turn the control valve handle to the up position Allow the chair to fully rise 3 Turn the control valve handle to the down position Allow the seat to lower to a fully down position Repeat steps 2 a...

Page 7: ... fully raised position when the lift is not in use and or when the water supply is turned off Use the 180 rotated lock pin hole upper hole to lock the chair in place when removing the lift from the anchors 4 To drain the water from the lift for storage disconnect the water source turn the control valve to down push the chair down turn the control valve to up and push the chair back up Repeating th...

Page 8: ...se steps several times to passivate the stainless steel Spectra Clean kits are available from Spectrum Part Number 202050 00 Do not spray with high pressure water only clean with non chlorinated water 2 Check all water connections Check any external hoses for wear and or breakage in the outer tubing 3 Check all mechanical connections inspect the Nylock Nuts on all moving parts and make sure they a...

Page 9: ... times up and down while assisting motion Call for assistance Replace Top Collar P N 27315 3 Lift moves up slowly Low water pressure Worn Seals Valve Failure Use lift with Booster Pump P N 27028 00 Replace Seals P N 27245 27246 Replace Valve P N 27285 27286 4 The seat travels much slower than normal Low battery Defective or worn out battery Recharge battery Replace battery 5 Lift descends with val...