TECHNICAL SUPPORT: (909) 259-6001
BLSW1016
Installation: Primary/Secondary Connections
Electrical Installation - Primary/Secondary:
The control board provides a connector for Primary/Secondary connectivity. This
connector will allow synchronized operation with a second gate operator.
Shielded Cable (#PA-PSC100)
NOTE: Use 16
Guage Wire for
runs up to 100’
Conduit
Shield Wire
Caution – Do not run Primary/Secondary communication
cable (Model #PA-PSC100) in the same conduit as the
power supply (120-220V) cable.
Inside
Outside
Primary
Secondary
Interconnecting Conduit
Blk\Wht
Green
Red
Silver
Silver
Blk\Wht
Green
Red
Note: It is recommended to connected all external devices and set timer on the Primary unit. Timer
setting on Secondary unit will be ignored.