TECHNICAL SUPPORT: (909) 259-6001
BLSW1016
29
Installation: Selectable Features
CLOSE TIMER:
LEAF DELAY:
INSTANT
REVERSING
SENSOR:
Close Timer
The Close Timer will close the gate a set time
after the vehicle clears the gate area. This is
adjustable from 3 to 60 seconds.
Leaf Delay
An Overlap Delay has been provided for
biparting gates that have an emblem or
maglock for example. It will provide up to a 3
second delay on primary or secondary
operator.
Instant Reversing Sensor
The Obstruction Sensor needs to be adjusted
to compensate for the installation and gate
weight. The overload adjustment is provided
to set the gate sensitivity.
a) If the gate reverses by itself or stops in
midcycle, it is too sensitive.
b) If the gate hits an object and does not
reverse or stop, it is not sensitive
enough.
c) Clockwise increases sensitivity, counter-
clockwise decreases sensitivity.
Test and adjust
for proper reversing pressure
(Note: When unit alarms, push “STOP” or
“RESET” button will clear the alarm)
BLSW1016 Manual_Layout 1 5/8/2015 5:06 PM Page 29