background image

Copyright Planika Sp. z o.o.  

www.planikafires.com 

 

 

 

 

 

 

READY

 

2.2. Insert the funnel. 

 

2.3 Pour the fuel into the funnel 

following these precautions

 

During pouring be careful not to spill fuel out of the filler. If the fuel is spilled error message is displayed 

 

 

 

 

go to step F, and follow the guidance provided in the table. 

If the spillage  

 

 

 

 

is excessive the source of power needs to be disconnected. 

 

 

If 5L containers are used to fill up, twist on the cap with the tap onto the container and pour using the 

funnel. To fill up use only accessories provided by the manufacturer.

 

 

 

 

 

2.4  Pour the fuel to the point where the blue indicator blinks  

      and the intermittent beep will 

sound. Stop pouring! Remove the funnel. 

2.5. Close the Fanola filler bolt. The green indicator   

 will flash on the control panel.                      . 

3.

 

Starting the device. The green indicator flashes on the control panel   

      .  

3.1. Press the 

START / STOP

 button on the control panel and hold for 2 seconds - You will hear a single beep. 

3.2. The green indicator will blink    

to indicate start-up of the device, it takes a few moments for the 

appliance to ignite the flame. 

3.3.  While  the  appliance  is  in  work  mode,  the  green  indicator  goes  off  and  the  flame  starts  to  appear.  The 
device works automatically until they run out of fuel or disable the device by the user. 

 

READY

FUEL

READY

READY

FUEL

HOT

Summary of Contents for PrimeFire 2

Page 1: ...USER S MANUAL PrimeFire 2 PF 0757 0000 000 Manufactured by Planika Sp z o o ul Bydgoska 38 86 061 Brzoza Poland Edition i0825 03 as of 18 03 2015 ...

Page 2: ...IS S I IN NS ST TR RU UC CT TI IO ON N M MA AN NU UA AL L TABLE OF CONTENTS I General information 3 II Fuel 3 III Safety 3 IV Operation Operating elements 5 Initial start up of the device 5 Flame size regulation 7 Device extinguishing 7 Subsequent start up 7 Information and warning alert 7 V Cleaning and maintenance 9 VI Disposal and recycling 9 ...

Page 3: ...ps regarding operation S 2 keep away from children S 7 the fuel tank should be tightly shut S 16 do not store in vicinity of sources of ignition do not burn S 46 in the event of ingestion consult a doctor and provide the packaging or label This mark stands for information which one needs to acquaint with This mark stands for warnings which one needs to acquaint with III Safety The PrimeFire produc...

Page 4: ... and cool down the elements before moving the device The device should not be left without adult supervision Prevent handling of the device by persons not trained Do not attempt to make changes or repairs to the construction of the device on your own Repairs can be made only by a person trained to service the device Do not pour FANOLA liquid to a furnace as it may cause damage of the device and ca...

Page 5: ... according to the instructions and the manual A Operating elements Control Panel v START STOP READY FUEL Planika HOT ERROR N E W S E N S O F F I R E PAT PEND ECO B Initial start up of the device 1 On the control panel the blue light flashes it indicates the lack of fuel in the tank Please refuel 2 Refueling 2 1 Open the Fanola filler bolt Service USB input hidden under a cap Starts the device from...

Page 6: ...cturer 2 4 Pour the fuel to the point where the blue indicator blinks and the intermittent beep will sound Stop pouring Remove the funnel 2 5 Close the Fanola filler bolt The green indicator will flash on the control panel 3 Starting the device The green indicator flashes on the control panel 3 1 Press the START STOP button on the control panel and hold for 2 seconds You will hear a single beep 3 ...

Page 7: ...ge will disappear and depending on the amount of the fuel in the tank either the green indicator will flash and indicate the readiness for operation or the blue indicator will indicate the lack of the fuel E Subsequent start up If on the control panel flashes the blue FUEL indicator start to run the product from the point B 2 If on the control panel flashes the green READY indicator you can start ...

Page 8: ...e of power needs to be disconnected With the use of the manual pump supplied by the manufacturer pump out at least 1 litre of fuel from the fuel filler Wait at least 1 hour to evaporate the remaining moisture and then close the fuel filler bolt Hold the ECO button for about 5 seconds If the alarm message reappears wait a little bit longer until the rest of the moisture evaporates If the message re...

Page 9: ...ean the inside of the device by unauthorized persons The manufacturer does not foresee a situation where it will be necessary to clean elements not normally available The manufacturer is not liable for damage resulting from improper operation non manual self dismantling attempts to modify using other liquids than those recommended in point II Fuel VI Disposal and recycling The product is equipped ...

Reviews: