Copyright Planika Sp. z o.o.
www.planikafires.com
3
I.
General information
The PrimeFire is a decorative appliance with real flames. Due to the innovative technology applied, the PrimeFire is
simple and safe to use.
II.
Fuel
In order for the PrimeFire to function correctly use the recommended FANOLA® liquid or other available on the
market and fulfilling the criteria of being a 86-96% denatured ethanol in accordance with the European Union
guidelines (Directive No. 162/2013).
Using other liquids is prohibited as it may lead to incorrect functioning of the device, damage of the device and/or
may cause fire or and/or health risk. The manufacturer takes no responsibility for damage caused by using prohibited
liquids such as absolute ethanol.
Explanation of symbols placed on the flap of the device:
It is forbidden to pour fuel into a burning device!
It is forbidden to pour fuel into a hot device!
FANOLA ® - additional information:
Warning sign:
F
– flammable material
Warning marking:
R-11
– flammable liquid
Tips regarding operation:
S-2
– keep away from children
S-7
– the fuel tank should be tightly shut
S-16
– do not store in vicinity of sources of ignition, do not burn
S-46
– in the event of ingestion consult a doctor and provide the packaging or label
This mark stands for information which one needs to acquaint with.
This mark stands for warnings which one needs to acquaint with.
III.
Safety
The PrimeFire produces a real open fire, so, in order to use the device properly and safely and in order
to keep the warranty, the following safety rules should be observed.
•
While installing the device in accordance with the manual one needs to observe national and local regulation.
•
If the device suddenly turns off one needs to follow point „F“ of the manual.
•
One needs to maintain the utmost care towards flammable materials.
•
The device may only be used in a room with minimum cubature of 58 m
3
. In order to use more than one
device in the room one needs to provide proportionally larger cubature (for two devices 116 m
3
(4097 ft
3
), for
three 174 m
3
(6146 ft
3
), etc.).
•
Operation of many appliances is only possible if the fuel flow does not exceed 0,5l/h and a separate
ventilation of the room is necessary.
OSTRZE
Ż
ENIE
!
OSTRZE
Ż
ENIE
!