It is recommended to regularly check the safety tray for presence of fuel. If there is fuel in the safety tray it 

needs to by dried. 

 

The device is not fit for constant operation. 

 

It is not permitted to use other liquids than the recommended FANOLA®. 

 

Do not expose the device to weather conditions. The product is for internal use only. 

 

Please read the device installation manual to avoid placing the device in rooms with a capacity of less than 

required. 

 

While working, the device emits heat, water vapour and carbon dioxide, therefore it is necessary to provide 

proper ventilation of the interior, so that the total air exchange is 1/h. 

 

During  the  device’s  starting  sequence  the  characteristic  smell  of  the  liquid  used  in  the  device  or  the 

recommended FANOLA® liquid. 

 

Do not install the device in areas of large drafts of air, near fans, vents, etc. 

 

Do not place in areas where  there  might be a potentially  explosive atmosphere of paint vapours, industrial 

dusts, etc.

 

 

Do  not  use  the  device  at  the  ambient  temperature  below  10°C  (50°  Fahrenheit)  or  higher  than  30°C  (86° 

Fahrenheit). 

 

Install  the  device  only  on  a  flat,  horizontal  surface.  Setting  on  an  inclined  surface  can  cause  incorrect 

operation, permanent damage to the device or cause fire. 

 

No flammable items should be placed in direct contact and within a radius of 1 m / 3.28 ft around the device. 

Do not place near curtains, net curtains, etc. 

 

It is obligatory to have a carbon-dioxide or dry chemical extinguisher placed nearby the device. 

 

The enabled device must not be moved. Wait for complete fuel burn-out, disconnect the power supply and 

cool down the elements before moving the device. 

 

The device should not be left without adult supervision. 

 

Prevent handling of the device by persons not trained. 

 

Do  not  attempt  to  make  changes  or  repairs  to  the  construction  of  the  device  on  your  own.  Repairs  can  be 

made only by a person trained to service the device. 

 

Do  not  pour  FANOLA  liquid  to  a  furnace,  as  it  may  cause  damage  of  the  device  and  cause  fire.  Pouring 

FANOLA liquid to a burning furnace may cause a sudden ignition and can cause fire, burns and a risk to life. 

 

Do not heat the FANOLA liquid before starting-up the device. 

 

Do not start up the device if the FANOLA liquid spilled out from the container. 

 

Do not cover the working device as it may cause fire. 

 

Keep the device and fuel away from children, pets and unauthorized persons. 

 

FANOLA liquid is not suitable for consumption. Avoid contact with skin and eyes. 

 

Do not operate by the filler when the device is running. 

 

Do not tamper with the elements inside the furnace body at the risk of burns, damage to the device or fire. 

 

Some  elements  of  the  device  heat  up  to  high  temperatures.  Do  not  touch  the  area  of  the  furnace  of  the 

device as it may cause burns. 

 

Do not place any decorative elements on the burner’s surface. 

 

Warning!  The  glowing  coil  temperature 

heats  up  to 

1300 

°

C.  Touching  the  device  while  it  is  turned  on  may 

cause burns. 

 

Warning! The furnace heats up to high temperatures during operation! 

 

WARNING! The first run can be made only after proper installation of the device and reading the manual 

instructions!

 

 

WARNING!  Prior  to  moving  the  appliance  burn  the  fuel  out  and  move  the  appliance  slowly,  in  the 

horizontal  position,  avoiding  shaking.  There  is  always  some  fuel  left  inside  the  device  and  if  spilled  the 
sensors might get wet. If that happens the appliance will not work until the liquid evaporates.

 

 
 
 
 
 
 
 
 
 
 

Summary of Contents for PrimeFire 2

Page 1: ...USER S MANUAL PrimeFire 2 PF 0757 0000 000 Manufactured by Planika Sp z o o ul Bydgoska 38 86 061 Brzoza Poland Edition i0825 03 as of 18 03 2015 ...

Page 2: ...IS S I IN NS ST TR RU UC CT TI IO ON N M MA AN NU UA AL L TABLE OF CONTENTS I General information 3 II Fuel 3 III Safety 3 IV Operation Operating elements 5 Initial start up of the device 5 Flame size regulation 7 Device extinguishing 7 Subsequent start up 7 Information and warning alert 7 V Cleaning and maintenance 9 VI Disposal and recycling 9 ...

Page 3: ...ps regarding operation S 2 keep away from children S 7 the fuel tank should be tightly shut S 16 do not store in vicinity of sources of ignition do not burn S 46 in the event of ingestion consult a doctor and provide the packaging or label This mark stands for information which one needs to acquaint with This mark stands for warnings which one needs to acquaint with III Safety The PrimeFire produc...

Page 4: ... and cool down the elements before moving the device The device should not be left without adult supervision Prevent handling of the device by persons not trained Do not attempt to make changes or repairs to the construction of the device on your own Repairs can be made only by a person trained to service the device Do not pour FANOLA liquid to a furnace as it may cause damage of the device and ca...

Page 5: ... according to the instructions and the manual A Operating elements Control Panel v START STOP READY FUEL Planika HOT ERROR N E W S E N S O F F I R E PAT PEND ECO B Initial start up of the device 1 On the control panel the blue light flashes it indicates the lack of fuel in the tank Please refuel 2 Refueling 2 1 Open the Fanola filler bolt Service USB input hidden under a cap Starts the device from...

Page 6: ...cturer 2 4 Pour the fuel to the point where the blue indicator blinks and the intermittent beep will sound Stop pouring Remove the funnel 2 5 Close the Fanola filler bolt The green indicator will flash on the control panel 3 Starting the device The green indicator flashes on the control panel 3 1 Press the START STOP button on the control panel and hold for 2 seconds You will hear a single beep 3 ...

Page 7: ...ge will disappear and depending on the amount of the fuel in the tank either the green indicator will flash and indicate the readiness for operation or the blue indicator will indicate the lack of the fuel E Subsequent start up If on the control panel flashes the blue FUEL indicator start to run the product from the point B 2 If on the control panel flashes the green READY indicator you can start ...

Page 8: ...e of power needs to be disconnected With the use of the manual pump supplied by the manufacturer pump out at least 1 litre of fuel from the fuel filler Wait at least 1 hour to evaporate the remaining moisture and then close the fuel filler bolt Hold the ECO button for about 5 seconds If the alarm message reappears wait a little bit longer until the rest of the moisture evaporates If the message re...

Page 9: ...ean the inside of the device by unauthorized persons The manufacturer does not foresee a situation where it will be necessary to clean elements not normally available The manufacturer is not liable for damage resulting from improper operation non manual self dismantling attempts to modify using other liquids than those recommended in point II Fuel VI Disposal and recycling The product is equipped ...

Reviews: