5.2 Maintenance Task Definition
Control gear (Uno and Plug Board) Maintenance
Check Ingress Protection Caps
Sockets and connectors not in use
should have an Ingress Protection Cap
installed to protect the contents from
ingress. These caps must be tightly
fitted to prevent water ingress.
!
WARNING! Water ingress at the
socket can cause electrical shorts,
and possible fire.
Cables and Connectors Maintenance
!
WARNING: DO NOT attempt to clean cables with a sharp object or knife.
Check for cable damage
This check is to ensure that the cable is intact and
undamaged. Inspect entire length of cable for nicks, kinks,
tension cracks, compression folds, stretched or crushed
portions. If there is damage, replace the cable.
!
WARNING! DO NOT attempt to clean the cable with a
sharp object or knife.
Check cable install
This check is to ensure that the cable is correctly installed.
The cable should be clipped, or taped to suspension ropes to
constrain and control the cable route. Cables should be neatly
routed and constrained to avoid unwanted damage, tangles,
and trip hazards.
Check contacts for corrosion
This check is to ensure that no corrosion is occurring to the
contact points within the plug and socket assembly.
Undo the locking nut, and remove the plug from the socket.
Inspect the both the male pins in the plug attached to cable,
and the female socket mounted to the box. If corrosion is
present order replacement parts, and replace immediately.