7. Monitor Information
This command provides the SICP protocol and the display software versions to the host
controller.
7.1 Model Number, FW Version, Build Date Message Get
Bytes
Bytes Description
Bits
Description
DATA[0]
0xA1 = Model
Number & FW
version of device with
Date- Get
Request the Model Number and FW version of the
device
DATA[1]
to
DATA[N]
Codes to request
0x00 = Model Number
0x01 = FW version
0x02 = Build Date
Example: Get model number (Display Address 01)
7.2 Model Number, FW Version, Build Date Message Report
Bytes
Bytes Description
Bits
Description
DATA[0]
0xA1 = Model
Number & FW
version of device with
Date- Report
Request the Model number, FW version, FW build
date
DATA[1]
to
DATA[N]
Character[0] to
Character[N-1]
36 (0x24) characters maximum.
No. of characters, N = 1 to 36 (0x24).
The actual size determines the value of the
message size byte.
Header
Monitor
ID
Category
Code0
Code1
Length
Data Control
Data[0]
Data[1]
Checksum
0xA6
0x01
0x00
0x00
0x00
0x04
0x01
0xA1
0x00
0x03