Miscellaneous
VM Series Displays RS232 User Guide
020-1359-00A
Page | 35
20.3 Tiling Set
Bytes
Bytes Description
Bits
Description
DATA[0]
0x22 = Tiling- Set
Command reports Tiling Setting
DATA[1]
Enable
0x00 = No
0x01 = Yes
DATA[2]
Frame comp.
0x00 = No
0x01 = Yes
0x02 = don’t overwrite (keep previous
value)
DATA[3]
Position
0x00 = don’t overwrite (keep previous
value)
0x01 = position 1
0x02 = position 2
till
DATA[4]
V monitors, H monitors
0x00 = don’t overwrite (keep previous
value)
0x01 = V monitors =1 H monitors =1
0x02 = V monitors =1 H monitors
=2 till
Example: Set the Display to the following: Tiling Enabled Yes, Frame comp. No, Position 2, V
Monitors=2, H monitors = 3 (Display Address 01)
Header
Monitor
ID
Category
Code0
Code1
Length
Data
Control
Data[0]
Data[1]
Data[2]
Data[3]
Data[4]
Checksum
0xA6
0x01
0x00
0x00
0x00
0x07
0x01
0x22
0x00
0x00
0x02
0x08
0x89
Example: Set the Display to the following: Tiling Enabled: Yes, Frame comp: keep as before, Position:
Keep as before, V Monitors, H monitors: keep as before (Display Address 01)
Header
Monitor
ID
Category
Code0
Code1
Length
Data
Control
Data[0]
Data[1]
Data[2]
Data[3]
Data[4]
Checksum
0xA6
0x01
0x00
0x00
0x00
0x07
0x01
0x22
0x01
0x02
0x00
0x00
0x80