22
To set the page scan time, set the
Precision/Speed
profile:
Profile
Parameter averaging
BER measurement limit
Fast
by 1 value
1E-6
Normal
by 2 values
1E-7
Precise
by 4 values
1E-8
4.4.4.4
Viewing the Measured Data of the Channel Data Logger
To view the Channel Data Logger page, press
«F1/Page»
and select
Open
. A table of general data
of the Channel Data Logger page will appear on the screen (Figure 4.15).
Figure 4.15
The table contains:
•
Page name
Name of the Channel Data Logger page;
•
Measured
Number of channels. Measured /Total;
•
State
Test result;
•
Defective an. ch.
Number of analog channels, with errors/total number;
•
Defective dig. ch.
Number of digital channels, with errors/total number;
•
Δ analog,dB
Ripple value for analog channels and permissible limit;
•
Δ digital,dB
Ripple value for digital channels and permissible limit;
•
Δ analog/digital,dB
Maximum level difference between analog and digital channels and
permissible limit.
If the parameter analysis is disabled in the limit plan, then in the table its status is marked as
Off
.