95
~
M
INIMUM DISTANCES REQUIRED FOR PROPER VENTILATION
C
=
V
ENTILATION SLOT
A
B
C
D
W
ALL CUPBOARD
➢
min. 760 mm
E
XTRACTOR HOOD
➢
min. 760 mm
min. 50 mm
min. 20 mm
Air inlet
The hob must be ventilated properly. The air inlet and outlet must never be
blocked or covered.
I
NSTALLATION OF THE HOB
1.
Before installing the hob, you must fix the adhesive seal on the
bottom
edge of
the hob properly.
The seal
must be
fitted tightly on the bottom edge of the hob (no overlaps, no
gaps etc.) to prevent liquids etc. from entering the installation opening
subsequently.
2.
Insert the hob in the opening and align it correctly. The hob must be in the
installation opening of the worktop properly and firmly. Check the seal for perfect
fit and overall cover.
Summary of Contents for BIC8 2KB-DPY