148
~
E
RROR CODE
E
RROR
D
ESCRIPTION
/ M
EASURES
E - 5
F
AILURE OF THE
COMMUNICATION
LINE
➢
Whenever the power board cannot
receive valid communication data from
the display board within 20 seconds, the
power board automatically switches off
all loads / connections.
E - 6
F
AILURE OF THE
COMMUNICATION
LINE
➢
If the display board cannot receive valid
communication data from the power
board within 20 seconds, the display
board sends data to close all
connections / loads.
E - 7
D
EFECTIVE
SENSOR OR
HEATING
ELEMENT CIRCUIT
➢
High-temperature
protection
is
provided and the loads / connections
are switched off within 10 seconds.
If any error code is indicated on the display
but the problem could not be
solved,
disconnect the appliance from the mains and contact the aftersales
service.
9. Technical data
T
ECHNICAL DATA
*
Model
Built-in oven with hob incl. pyrolysis
Control panel
Stainless steel
Material: hob
Glass ceramic incl. aluminium frame
Energy efficiency category**
A
Energy efficiency index
92.80
Energy consumption / conventional
0.76 kW/h
Energy consumption (fan / hot air)
0.82 kW/h
Net volume oven in l
64.00
Number of heat sources per cooking
chamber
1 (electric)
Number of cooking chambers
1
Size of the appliance
Medium: volume < 65 l
Cooking zones
2 + 1 dual cooking zone
+ 1 oval cooking zone
(4 in total)