 1 INFORMATION ON THIS DOCUMENT

1.1 Function

The present operating instructions provide information on installation, connection and 
safe use for the following articles: 

CS AR-04••••.

1.2 Target audience

The operations described in these operating instructions must be carried out by quali-
fied personnel only, who are fully capable of understanding them, and with the techni-
cal qualifications required for operating the machines and plants in which the safety 
devices are to be installed.

1.3 Application field

These instructions apply exclusively to the products listed in paragraph Function, and 
their accessories.

1.4 Original instructions

The Italian language version is the original set of instructions for the device. Versions 
provided in other languages are translations of the original instructions.

 2 SYMBOLS USED

 This symbol indicates any relevant additional information

 Attention: Any failure to observe this warning note can cause damage or mal-

function, including possible loss of the safety function.

 3 DESCRIPTION

3.1 Device description

The safety device described in this manual is defined according to the Machinery 
Directive 2006/42/EC as logic component for safety functions.
The safety modules to which these usage instructions refer are devices specifically 
designed and manufactured for use on industrial machines. Upon opening of at least 
one channel, the safety function ensures that the safety relays must open their output 
contacts within the defined reaction time. The safety outputs of the module are ena-
bled only if the channels CH1 and CH2 are consistently closed and after activating 
the START signal.

3.2 Device functions

 This device is suitable for the following applications: as a module for emergency 

stop, for end position monitoring with movable guards, for magnetic safety sensors in 
safety circuits up to category 4 acc. to EN ISO 13849-1, up to SIL 3 acc. to EN 62061 
and up to PL e acc. to EN ISO 13849-1. 
- Input with 1 or 2 channels.
- The SIL 3 / PL e safety function is only available with the two redundant inputs 
configuration.
- Output contacts: 3 NO safety contacts, 1 NC auxiliary contact.
- Choice between automatic start, manual start or monitored start.

 With reference to the "automatic" operating mode, consider RES 1.2.3 of the 

Machinery Directive 2006/42/EC: "For machinery functioning in automatic mode, the 
starting of the machinery, restarting after a stoppage, or a change in operating condi-
tions may be possible without intervention, provided this does not lead to a hazardous 
situation".
- Connection of input channels of opposite potentials.
- Short circuit detection function of the control elements by means of safety system 
with self-monitoring and redundancy.
- LED indicators for switching state of the channels 1, 2 and for the power supply 
voltage.
- Without muting input, no bridging of the safety function.
- In the event of a failure, the device switches to a safe state and deactivates the 
safety output. 
- Screw terminals or plug-in terminals with screw connections or spring terminals (de-
pending on the model).
- Snap-mounting on DIN rails.

3.3 Intended use of the device

- The device described in these operating instructions is designed to be applied on 
industrial machines.
- The direct sale of this device to the public is prohibited. Installation and use must be 
carried out by qualified personnel only.
- The use of the device for purposes other than those specified in these operating 
instructions is prohibited.
- Any use other than as expressly specified in these operating instructions shall be 
considered unintended by the manufacturer. 
- Also considered unintended use:
a) using the device after having made structural, technical, or electrical modifications 
to it;
b) using the product in a field of application other than as described in paragraph 
TECHNICAL DATA.

 4 OPERATION

4.1 Operating diagram

Automatic 
start:

A1/A2

S11/S12

S21/S22

13/14, 23/24, 33/34

31/32

t

C

t

A

t

R1

t

R1

t

C

t

A

t

R

t

A

Monitored 
start:

A1/A2

S11/S12

S21/S22

S12/S34 (START)

31/32

t

A

t

R1

t

R1

t

A

t

R

t

MIN

t

A

13/14, 23/24, 33/34

Manual start:

t

A

t

R1

t

R1

t

A

t

R

t

MIN

A1/A2

S11/S12

S21/S22

S12/S34 (START)

31/32

13/14, 23/24, 33/34

Legend:

t

MIN

:

 Min. duration of start impulse

t

C

:

 Simultaneity time

t

A

:

 Response time

t

R1

:

 Release time

t

R

:

 Release time in absence of power 

supply

Notes: The configurations with one channel are obtained taking into consideration only 
the effect of the S11/S12 input on the supply. In this case it is necessary to consider 
time t

R1

 referred to input S11/S12, time t

R

 referred to the supply, time t

A

 referred to input 

S11/S12 and to the start, and time t

MIN

.

4.2 Wiring diagrams

Emergency stop circuits

Input configuration with manual start 

1 channel

Input configuration with manual start

2 channels

S12

S11

S35

S21

S22

A1

S34

A2

CS AR-04

L / +

N / -

S12

S11

S35

S21

S22

A1

S34

A2

CS AR-04

L / +

N / -

S12

S34

S34

S12

Automatic start

With regard to the indicated diagrams, short-circuit the start 
button between the S12 and S34 terminals in order to acti-
vate the automatic start module.

S21

S22

S21

S22

S35

S35

Monitored start

With regard to the indicated diagrams, remove the connec-
tion between the S22 and S35 terminals in order to activate 
the monitored start module.

Monitoring of movable guards and magnetic safety 
sensors

The safety module can monitor emergency stop circuits, 
control circuits for movable guards as well as magnetic 
safety sensors. Replace the emergency stop contacts with 
switch contacts or sensor contacts.

Magnetic sensors can be connected only in dual 
channel configuration.

Summary of Contents for CS AR-04 Series

Page 1: ... di rilevamento del cortocircuito degli organi di comando tramite sistema di sicurezza con autocontrollo e metodo di ridondanza Indicatori LED dello stato di commutazione dei canali 1 2 e della tensione d alimen tazione Ingresso di muting o esclusione della funzione di sicurezza non presente In caso di guasto il dispositivo si porta in stato sicuro disattivando l uscita di sicu rezza Morsetti con ...

Page 2: ...e assicurarsi che l intera macchina o il sistema sia conforme alle norme applicabili e ai requisiti della Direttiva Compatibilità Elettroma gnetica La documentazione necessaria per una corretta installazione e manutenzione è sempre disponibile nelle seguenti lingue inglese francese tedesco italiano Nel caso l installatore non sia in grado di comprendere pienamente la documenta zione non deve proce...

Page 3: ...o circuito resistenza PTC Ih 0 5 A Tempi della PTC intervento 100 ms ripristino 3 s Resistenza massima per ingresso 50 Ω Corrente per ingresso 30 mA Durata minima impulso di start tMIN 100 ms Tempo di eccitazione tA 50 ms Tempo di ricaduta tR1 20 ms Tempo di ricaduta in mancanza di alimentazione tR 70 ms Tempo di contemporaneità tC infinito 9 5 Circuito d uscita Contatti d uscita 3 contatti NO di ...

Page 4: ...tials Short circuit detection function of the control elements by means of safety system with self monitoring and redundancy LED indicators for switching state of the channels 1 2 and for the power supply voltage Without muting input no bridging of the safety function In the event of a failure the device switches to a safe state and deactivates the safety output Screw terminals or plug in terminal...

Page 5: ...an Should the installer be unable to fully understand the documents the product must not be installed and the necessary assistance may be requested from the manufac turer see paragraph SUPPORT Always attach the following instructions to the manual of the machine in which the device is installed These operating instructions must be kept available for consultation at any time and for the whole perio...

Page 6: ...it Output contacts 3 NO safety contacts 1 NC auxiliary contact Contact type forcibly guided Material of the contacts gold plated silver alloy Maximum switching voltage 230 240 Vac 300 Vdc Max current per contact 6 A Conventional free air thermal current Ith 6 A Max total current Σ Ith 2 64 A2 Minimum current 10 mA Contact resistance 100 mΩ External protection fuse 4 A Maximum switching load 1380 V...

Page 7: ...ereuse Raccordement des canaux d entrée à potentiels opposés Fonction de détection du court circuit des éléments de commande par système de sécurité avec autocontrôle et méthode de redondance Indicateurs LED de l état de commutation des canaux 1 2 et de la tension d alimen tation Pas d entrée d inhibition pas d exclusion de la fonction de sécurité En cas de défaillance le dispositif passe dans un ...

Page 8: ...spositif comme support ou appui pour d autres structures che mins guides de glissement ou autres Avant la mise en service veiller à ce que l ensemble de la machine ou le système soient bien conformes aux normes applicables et aux exigences de la Directive sur la compatibilité électromagnétique La documentation requise pour une installation et un entretien corrects est toujours disponible dans les ...

Page 9: ...c 50 60 Hz art CS AR 04 230 Tolérance sur la tension d alimentation 15 d Un Ondulation résiduelle max DC 10 Absorption AC 5 VA Absorption DC 2 W 9 4 Circuit de contrôle Protection contre les courts circuits résistance PTC Ih 0 5 A Temps de la PTC déclenchement 100 ms réarmement 3 s Résistance maximale par entrée 50 Ω Courant par entrée 30 mA Durée min impulsion de démarrage tMIN 100 ms Temps d exc...

Page 10: ...ingangskanälen mit entgegengesetzten Potenzialen Funktion zur Kurzschluss Erkennung der Befehlsgeber durch Sicherheits System mit Eigenüberwachung und Redundanz LED Anzeigen für den Schaltzustand der Kanäle 1 2 und für die Versorgungsspan nung Ohne Mutingeingang keine Unterdrückung der Sicherheits Funktion Bei einer Störung geht das Gerät in einen sicheren Zustand und deaktiviert den Sicherheits A...

Page 11: ...n des Moduls gemäß den Angaben der Ablaufdiagramme prüfen siehe Abschnitt BETRIEB Die Anschlusskabel dürfen nicht übermäßig verbogen werden um Kurzschlüsse und Unterbrechungen zu vermeiden Das Gerät keinesfalls lackieren oder bemalen Das Gerät niemals anbohren Verwenden Sie das Gerät nicht als Stütze oder Ablage für andere Strukturen wie z B Kabelkanäle oder Gleitführungen Stellen Sie vor der Inbe...

Page 12: ...g Ui 250 V Überspannungskategorie II Luft und Oberflächenabstände gemäß EN 60947 1 9 3 Stromversorgung Nennversorgungsspannung Un 24 Vac dc 50 60 Hz Art CS AR 04 024 120 Vac 50 60 Hz Art CS AR 04 120 230 Vac 50 60 Hz Art CS AR 04 230 Versorgungsspannungstoleranz 15 von Un Max DC Restwelligkeit 10 Leistungsaufnahme AC 5 VA Leistungsaufnahme DC 2 W 9 4 Steuerkreis Kurzschlussschutz PTC Widerstand Ih...

Reviews: