91
32.2 Function Master
Software functions of ATR620 include operating as Master. This feature
allows serial communication of several controllers to control more zones
of the same kiln. Function is enabled entering 0 on parameter 50. Master
will communicate Start/Stop of cycle and setpoint values to the
connected slave units (which must be configurated for remote setpoint
on parameters 1 and 5). Communication follows the broadcast mode: all
controllers receive data. If Waiting function is enabled on Master, it will
read process values of the first 16 connected controllers (slave address
1 to 16 on parameter 50) and it will check eventual delay of any
connected zone.
32.3 Word addresses ATR620
Modbus
address
Description
Read
Write
Reset
value
1
Process AN1
R
0
2
Process AN2
R
0
3
Ambient temperature
R
0
4
Output % process 1
R/W
0
5
Output % process 2
R/W
0
6
Setpoint 1
R/W
EEP
7
Setpoint 2
R/W
EEP
8
Remote setpoint
R
EEP
9
Setpoint 1 via serial communication
R/W
EEP
10
Setpoint 2 via serial communication
R/W
EEP
11
Delaied start (waiting time at start)
R/W
EEP
15
Start via serial communication
R/W
0
21
Parameter 1
R/W
EEP
22
Parameter 2
R/W
EEP
23
Parameter 3
R/W
EEP
24
Reserved
R
?
25
Parameter 5
R/W
EEP
26
Parameter 6
R/W
EEP
27
Parameter 7
R/W
EEP
28
Parameter 8
R/W
EEP
29
Parameter 9
R/W
EEP
30
Parameter 10
R/W
EEP
31
Parameter 11
R/W
EEP
32
Parameter 12
R/W
EEP
33
Parameter 13
R/W
EEP
34
Parameter 14
R/W
EEP