75
29 List of configuration parameters
P-01
General configuration
This parameter selects the type of P.I.D. action, enables
operator’s access to special functions like manual control of
output percentage 0-100%, Autotuning, delayed start, operating
as “Simple controller” with fixed setpoint beside standard
programming function, possibility to modify cycle data during the
cycle, programming of a starting setpoint (to assure the
programmed rising gradient in case that kiln temperature at cycle
start is too high), number of cycles available to the operator,
remote control for cascade applications..
1
st
Digit – Type of PID control
0
Single reverse action (Heating)
1
Single direct action (Cooling)
2nd
Digit – Access to following functions:
Auto-tuning
Simple controller
Delaied start
0
No
No
No
1
Yes
No
No
2
No
Yes
No
3
Yes
Yes
No
4
No
No
Yes
5
Yes
No
Yes
6
No
Yes
Yes
7
Yes
Yes
Yes
3
rd
Digit – Access to following functions
Manual %
Output
Starting setpoint
Modify data during
the cycle
0
No
No
No
1
Yes
No
No
2
No
Yes
No
3
Yes
Yes
No
4
No
No
Yes
5
Yes
No
Yes
6
No
Yes
Yes
7
Yes
Yes
Yes