User manual - ATR 142
19
output percentage command unchanged as generated
by the PID immediately before breakage.
7.7
Pre-Programmed Cycle
Pre-programmed cycle function activates by setting
pr.cY.
on
parameter 48
op.Mo.
Controller reaches setpoint1 basing on the gradient set on pa-
rameter 51
Grad.
, then it reaches max. power up to setpoint2.
When the process reaches max. power, this setpoint is main-
tained for the time set on parameter 52
ma.t.i.
At expiry, process will reach ambient temperature according
to gradient entered on parameter 64
fa.Gr.
, then command
output will be disabled and display will visualize
Stop
.
Setpoin
t
Time
Setpoint 1
Setpoint 2
Maintenance time
Mantenimento
Cooling
Raffreddamento
Max Power
Max Potenza
Rising gradient
Gradiente di salita
Cycle starts at each activation of the controller, or via digital
input if it is enabled for this type of functioning (parameter
50
dGt.i.
).