Using the pump unit in a dry state, i.e. with no fluid or with insufficient fluid, can damage it
irreparably. Dry pumping increases the operating speed of the pneumatic motor, resulting
in overheating and possible failure.
If operating at low temperatures, we recommend that you use systems to protect against
the formation of ice.
Don’t shut off the air supply while the pump is working. For its correct working never go
down below the declared pressure.
ATTENTION
MAINTENANCE
14.
Safety instructions
The system is designed and manufactured to require minimal
maintenance. Before carrying out any maintenance operation, it is
imperative to decompress the dispensing system with the aid of the
bleed ball valves. It is strictly forbidden to carry out any maintenance
operation if the circuit contains compressed air capable of causing the
pump to start suddenly.
Personal protective equipment (PPE) must be worn when carrying out
maintenance work.
Take account of the following minimum recommendations for correct
operation of the pump.
Authorised
maintenance
personnel
All maintenance must be performed by qualified personnel.
Tampering
can lead to performance degradation, danger to persons and/or
property and may result in the warranty being voided.
Measures to be
taken
Make sure that the label affixed to the dispensing system does not
deteriorate over time or come off.
EVERY DAY:
¦ check that the hoses are in sound condition.
ONCE A YEAR:
¦ check the components of the air circuit.
Summary of Contents for P 3.5
Page 20: ...20 112 Installation utilisation et entretien Bulletin M0352 rev 01 FR FRANÇAIS ...
Page 38: ...38 112 Installation Gebrauch und Wartung Bulletin M0352 rev 01 DE DEUTSCH ...
Page 56: ...56 112 Installazione uso e manutenzione Bulletin M0352 rev 01 IT ITALIANO ...
Page 74: ...74 112 Instalación uso y mantenimiento Bulletin M0352 rev 01 ES ESPANOL ...
Page 92: ...92 112 Instalação uso e manutenção Bulletin M0352 rev 01 PT PORTUGUÊS ...
Page 110: ......
Page 111: ...PIUSI P 3 5 PIUSI P 5 5 ...