16
/112
Installation, use and maintenance
M0352
rev
.01 EN
We recommend that you adjust the pressure to the minimum quantity of
air necessary to obtain the desired dispensing results. Take the utmost care
when adjusting the pressure.
Normal use
13.
OPERATION
After initial priming, if the air line is open, opening the dispensing valve will
immediately start the pneumatic pump. Closing the dispensing valve will stop
the pneumatic pump.
NOTE
First use
To make optimum use of the pneumatic pump, we strongly recommend
that you follow the procedure set out below. This reduces risks for the
operator. After installation of the product, the starting state must involve
closure of all the ball valves in the air line, and closure of the dispensing
device and the pressure regulator with pressure gauge.
Opening the
air line
Keeping the pressure regulator in the closed position, open the air line
ball valves in sequence. Then keep the dispensing valve open over a
suitable metal container to receive the fluid from it once the system is
primed. Take extreme care and keep the dispensing nozzle in contact
with the wall of the container. We also recommend that you wear
personal protective equipment.
Opening the
pressure and
priming
Slowly open the pressure regulator with pressure gauge, as gradually as
possible. Monitor the pressure by means of the pressure gauge indicator
and wait until you hear the pneumatic pump come into operation to allow
priming. As soon as all the air in the fluid line has been expelled and the
dispensing valve has started dispensing, close the dispensing valve.
The system supplies fluids at high pressure, such a pressure as to be a
source of danger for the operator. Supply with caution the first time, and in
conditions of maximum safety, in order to acquire a correct perception of
the operation of the system.
Interrupt supply immediately if there are sparks or electrical discharge.
WARNING
Summary of Contents for P 3.5
Page 20: ...20 112 Installation utilisation et entretien Bulletin M0352 rev 01 FR FRANÇAIS ...
Page 38: ...38 112 Installation Gebrauch und Wartung Bulletin M0352 rev 01 DE DEUTSCH ...
Page 56: ...56 112 Installazione uso e manutenzione Bulletin M0352 rev 01 IT ITALIANO ...
Page 74: ...74 112 Instalación uso y mantenimiento Bulletin M0352 rev 01 ES ESPANOL ...
Page 92: ...92 112 Instalação uso e manutenção Bulletin M0352 rev 01 PT PORTUGUÊS ...
Page 110: ......
Page 111: ...PIUSI P 3 5 PIUSI P 5 5 ...