M0239
18
/32
Installation, use and maintenance
8 INSTALLATION
Due to limited weight and dimensions the use of special handling or lifting equipment is not re-
quired. When handling manually, usual personal protective devices should be worn. Upon receiv-
ing, pump package should be checked for damages and then stored in a dry area.
Always use pump only and exclusively for application allowed by this manual and in accordance
with normative safety standard.
Verify that no damage effect the pump during transportation or storage. Both inlet and outlet
ports should be then carefully cleaned removing dust or packaging materials..
Verify that available electrical power supply corresponds to the pump specification requirements.
Pump can be mounted in any position. Fix the pump using suitable screws corresponding to anti-
vibration mounts.
WARNING!
PUMP MOTOR IS NOT EXPLOSION PROOF.
Do not install the pump where flammable vapours or gases may be present. Install the
pump in a place accessible for inspection. Pump is IP65 protection rated.
9
HOSES CONNECTION
1 Before making any hose connections check that inlet ports have no caps.
do not position pump higher than 1.30mtr from minimum level of the fluid.
2 Pump damages may occur whether this height is exceeded as the pump do not draw fluid.
3 make sure the outlet hose is empty and without chokes. Inlet or outlet chokes can reduce pump
efficiency.
3 the use of an inlet filter is mandatory especially with fluid containing impurities.
4 Use only hose and connections resistant to fluids handled and avoid any possible environmental
dispersion.
10
START UP
electrical installation of the pump must include a protection fuse suitably rated as requested on
motor label and sized with chosen point of application.
WARRANTY EXPIRES IF NO FUSE IS USED.
REQUESTED FUSE:
GARDA1 12V
GARDA1 24V
GARDA2 12V
GARDA2 24V
25A
15A
35A
20A
NB. The fuse protects the pump from short-circuit.
Pump has no by-pass inside and maximum pressure can not in any way be overcome
10.1 MAXIMUM PRESSURE :
GARDA1 12V-24V
GARDA2 12V-24V
1.5BAR
1.5BAR
Antivibration rubbers have always to be mounted on pump to reduce noise and vibration.
Cables size depends on the distance between pump and battery. The use of undersized cabling
can cause overheating of the electrical wiring and therefore fire danger in anyway there will be a
voltage drop and a reduction in efficiency.
Summary of Contents for Nala Motors GARDA1
Page 2: ...M0239 2 32 Installazione uso e manutenzione Bulletin M0239 ITALIANO ...
Page 12: ...M0239 12 32 Installation use and maintenance Bulletin M0239 ENGLISH ...
Page 24: ...M0239 24 32 Installation use and maintenance GARDA 1 12 24 V GARDA 2 12 24 V ...
Page 26: ...M0239 26 32 Installation use and maintenance ...
Page 28: ...M0239 28 32 Installation use and maintenance ...
Page 30: ...M0239 30 32 Installation use and maintenance ...
Page 31: ......