This manual is the property of PIUSI S.p.A. Any reproduction, even partial, is forbidden.
ENGLISH (Translated from Italian)
GARDA1 - GARDA2
2
SAFETY INSTRUCTIONS
Mains - prelimi-
nary checks be-
fore installation
ATTENTION
You must avoid any contact between the electrical power sup-
ply and the fluid that needs to be FILTERED.
Maintenance
control
Before any checks or maintenance work are carried out, dis-
connect the power source.
FIRE AND
EXPLOSION
When flammable
fluids are present
in the work area,
such as gasoline
and windshield
wiper fluid, be
aware that flam-
mable fumes can
ignite or explode.
To help prevent fire and explosion:
Use equipment only in will ventilated area.
Keep work area free of debris, including rags and spilled or open
containers of solvent and gasoline.
Do not plug or unplug power cords or turn lights on or off when flam-
mable fumes are present.
Ground all equipment in the work area.
Stop operation immediately if static sparking occurs or if you feel
a shock. Do not use equipment until you identify and correct the
problem.
Keep a working fire extinguisher in the work area.
ELECTRIC
SHOCK
Electrocution or
death
F
This equipment must be grounded. Improper grounding, setup or
usage of the system can cause electric shock.
Turn off and disconnect power cord before servicing equipment.
Connect only to a grounded electrical outlets.
Use only 3 wire extension cords in accordance with local electrical codes.
Extension cords should have a ground lead.
Ensure ground prongs are intact on power and extension cords.
Do not expose to rain. Store indoors.
Never touch the electric plug of socket with wet hands.
Do not turn the dispensing system on if the power connection cord
or other important parts of the apparatus are damaged, such as the
inlet outlet plumbing, dispensing nozzle or safety devices. Replace
damaged components before operation.
Before each use check that the power connection cord and power
plug are not damaged. If damaged, have power connection cord re-
placed before use by a qualified electrician.
The electrical connection between the plug and socket must be kept
well away from water.
Unsuitable extension leads can be hazardous, in accordance with current
regulations. Only extension cords that are labelled for outdoor use and
have a sufficient conduction path should be used outdoors.
For safety reasons, we recommend that, in principle, the equipment be
used only with a earth-leakage circuit breaker (max 30 mA).
Electrical connections must use ground fault circuit interrupter (GFCI).
Installation operations are carried out with the box open and accessible
electrical contacts. All these operations have to be done with the unit
isolated from the power supply to prevent electrical shock!
Summary of Contents for Nala Motors GARDA1
Page 2: ...M0239 2 32 Installazione uso e manutenzione Bulletin M0239 ITALIANO ...
Page 12: ...M0239 12 32 Installation use and maintenance Bulletin M0239 ENGLISH ...
Page 24: ...M0239 24 32 Installation use and maintenance GARDA 1 12 24 V GARDA 2 12 24 V ...
Page 26: ...M0239 26 32 Installation use and maintenance ...
Page 28: ...M0239 28 32 Installation use and maintenance ...
Page 30: ...M0239 30 32 Installation use and maintenance ...
Page 31: ......