12 DISPOSAL
Foreword
If the system needs to be disposed, the parts which make it up must be delivered to companies
that specialize in the recycling and disposal of industrial waste and, in particular:
Disposing of
packing materials
The packaging consists of biodegradable cardboard which can be delivered to companies for
normal recycling of cellulose.
Metal Parts
Disposal
Metal parts, whether paint-finished or in stainless steel, can be consigned to scrap metal col-
lectors.
Disposal of
electric and
electronic com-
ponents
These must be disposed of by companies that specialize in the disposal of electronic compo-
nents, in accordance with the indications of directive 2012/19/UE (see text of directive below).
Information
regarding the
environment for
clients residing
within the Euro-
pean Union
European Directive 2012/19/UE requires that all equipment marked with this symbol on the
product and/or packaging not be disposed of together with non-differentiated urban waste.
The symbol indicates that this product must not be disposed of together with normal house-
hold waste. It is the responsibility of the owner to dispose of these products as well as other
electric or electronic equipment by means of the specific refuse collection structures indicated
by the government or the local governing authorities.
Disposing of RAEE equipment as household wastes is strictly forbidden. Such wastes must be
disposed of separately.
Any hazardous substances in the electrical and electronic appliances and/or the misuse of
such appliances can have potentially serious consequences for the environment and human
health.
In case of the unlawful disposal of said wastes, fines will be applicable as defined by the laws
in force.
Miscellaneous
parts disposal
Other components, such as pipes, rubber gaskets, plastic parts and wires, must be disposed of
by companies specialising in the disposal of industrial waste.
13 MALFUNCTIONS
Problem
Possible Cause
Remedial Action
LCD: BLINKING battery icon
Battery low
Replace batteries
Not enough measurement pre-
cision
Wrong K FACTOR
Referring to section C, check the cali-
bration factor
Il contalitri funziona sotto la minima por-
tata accettabile.
The meter works below minimum ac-
ceptable flow rate
The meter does not count, but
the flow rate is correct
Incorrect installation of gears after
cleaning
Repeat the reassembly procedure
Possible electronic board problems
Contact your dealer
High loss of head
Dirty filter
Clean the filters
Braked gears
Clean the measurement chambers
LCD: “HI FLO” is displayed
The meter is exceeding the maximum
allowed flow rate
Decrease the flow rate
LCD: “E1 CH1” is displayed
In chamber 1 no fluid is passing because
gears are blocked.
Check gears in chamber 1
Possible electronic board problems
Contact your dealer
LCD: “E1 CH2” is displayed”
In chamber 2 no fluid is passing because
gears are blocked.
Check gears in chamber 2
Possible electronic board problems
Contact your dealer
LCD: “E2 CH1” is displayed
fluid in chamber 2 is slower than fluid in
chamber 1
Check gears chamber 1
LCD: “E2 CH2” is displayed
fluid in chamber 2 is slower than fluid in
chamber 1
Check gears chamber 2