M0158B ITEN
48
/56
Installation, use and maintenance
9.2 (OPTIONAL) PULSE TRANSMITTER (PULS OUT)
For the models in which the function is available, there is an “Open Collector” type “Puls Out” output, which
emits 10 impulses per Unit of Measurement of the partial quantity that is dispensed. The number of pulses per
unit is fixed and it is set to 10 p\unit.
By connecting the Puls OUT output to a Display Repeater (“Puls IN Remote Display) and connecting the “Sync
reset” output (see logical connection shown below) it is possible to synchronise the 2 counters in measurement
as well as in reset.
PULSER
COUNTER
K900 WITH
PULSE OUT
REMOTE
DISPLAY
PULSE IN
10 pulse/unit
10 ALARM OUTPUT (ALARM OUT)
Nei modelli che prevedono l’uscita Puls Out, è disponibile anche un’uscita “Alarm Out”, del tipo “Open Col-
lector”, che si attiva quando si verifica una condizione di errore. L’uscita “Alarm Out” può essere collegata
ad un relè per pilotare una segnalazione di errore remota. Tale collegamento è opzionale, quindi è possibile
utilizzare l’uscita Puls Out senza dover necessariamente usare anche l’uscita Allarme.
REMOTE
DISPLAY
PULSE IN
K900
WITH
PULSE
OUT AND
ALARM
OUT