Pittway Notifier NIB-96 Manual Download Page 1

the NIB - 96

Network Interface Board

for the System 500, System 5000, AFP-200, AFP-400

and AM2020/AFP1010 Fire Alarm Control Panels

with NIB software P/N 73454 or higher

12 Clintonville Road
Northford, CT  06472
Phone: 203-484-7161
Fax: 203-484-7118

Document #     15666
10/15/97       Revision

D

P/N 15666:D1       ECN 97-407

Technical Manuals Online! - http://www.tech-man.com

Summary of Contents for Notifier NIB-96

Page 1: ...AFP 400 and AM2020 AFP1010 Fire Alarm Control Panels with NIB software P N 73454 or higher 12 Clintonville Road Northford CT 06472 Phone 203 484 7161 Fax 203 484 7118 Document 15666 10 15 97 Revision...

Page 2: ...Document 15666 Rev D 9 19 96 2 Technical Manuals Online http www tech man com...

Page 3: ...ation 17 Section Six AM2020 AFP1010 Slave Installation 20 Section Seven Slave AM2020 AFP1010 Programming 23 Section Eight Master AM2020 AFP1010 Programming 24 Section Nine Master System 5000 Programmi...

Page 4: ...581 The Voice Alarm System 5000 15890 The System 500 Manual 15019 The AFP 200 Manual 15511 The AFP 400 Installation Manual 50253 The AFP 400 Programming Manual 50259 The AFP 400 Operating Manual 50260...

Page 5: ...and AFP 400 DIP Switch AM2020 AFP1010 S5000 S500 AFP 200 AFP 400 1 AUTO ACK ON ON ON ON ON 2 TIMED ACK ON OFF ON OFF OFF 3 AM2020 AFP1010 SLAVE ON OFF OFF OFF OFF 4 NOT USED OFF OFF OFF OFF OFF 5 AM2...

Page 6: ...otes 1 Up to 10 LIB SLC loops can be installed in a master AM2020 2 Up to four LIB SLC loops can be installed in a master AFP1010 3 Each LIB SLC loop can support a maximum of 12 NIB 96 boards 8 points...

Page 7: ...maining 88 NIB points can be used in multiples of eight to display the status of AFP zones 1 to 88 6 The Master can not activate AFP zones 7 The Master can perform the following functions Signal Silen...

Page 8: ...in stallation of more LIBs or AIM 200s The capacity of a 10 loop master panel is 960 total slave points less four CPU points for each slave To Remote Station or Municipal Box see Note 3 System 5000 w...

Page 9: ...gether in a software zone and only reporting alarm or trouble for the software zone This technique allows very large system point capacity However a user at the master FACP may not be able to determi...

Page 10: ...panels connect to one or more LIB modules in the AM2020 AFP1010 Master The wiring requirements to connect to the LIB SLC loop are defined in Document 15088 NFPA Standards System 5000 Master Systems W...

Page 11: ...30E Audio Amplifier and speaker telephone circuit modules are located in the System 5000 The speaker telephone modules in the System 5000 may be the VCM 4 VCE 4 or DCM 4 See Figure 2 5 for the NIB 96...

Page 12: ...are supervised and power limited EOL Resistor Speaker Circuits Telephone Circuits EOL Resistor To additional Slave S5000 Audio Loop SLC Loop To NIB 96 Phone Loop To NIB 96 Slave System 5000 Slave Sys...

Page 13: ...ions are power limited and supervised See Sections 3 4 and 5 for details on connection requirements See diagram below for terminal assignment POWER IN connection to Main Power Supply if not mounted in...

Page 14: ...000 See Figure 4 2 for wiring diagram and all terminal assignments Connect the EIA 485 annunciator signal from the two terminal connector on the lower CPU board TB 2 to the NIB EIA 485 IN terminals Co...

Page 15: ...esponds to the number of slave circuits that the master control panel will monitor as individual points The SIZE of the System 5000 is usually eight times the number of modules installed including the...

Page 16: ...e controlled by the master control panel and have alarms from one slave activate output circuits in a different slave do not program any I O map in the slave System 5000 Perform all control by event m...

Page 17: ...See Figure 5 1 Electrical Installation Connect the main power harness from the System 500 power supply to P3 on the NIB Connect the power harness provided with the NIB from P2 on the NIB to the CPU 5...

Page 18: ...ever if the master panel must control the output of IC 4L ICR 4L modules the SIZE switch should be set to 6 one IC 4L ICR 4L using points 41 44 or 7 two IC 4L ICR 4L using points 41 44 and 49 52 Note...

Page 19: ...nd relays as a function of initiating circuits the System 500 must be programmed as follows 1 If the network system is to be controlled by the master control panel and have alarms from one slave activ...

Page 20: ...installation of an additional chassis As an alternative the AM2020 AFP1010 may use a CHS 4 chassis to mount the NIB See Figure 4 1 for mounting the NIB in a CHS 4 chassis Note also that the AM2020 AF...

Page 21: ...di tional NIBs are installed the power harness is daisy chained through all NIBs If the NIB is mounted to an ICA 4 4L All power connections are completed through the ICA 4 4L connection Connect the EI...

Page 22: ...t Address Settings The START ADDRESS switches are set for the desired address from the master SLC loop The NIB will answer all module addresses from START ADDRESS to START ADDRESS SIZE 1 inclusive Not...

Page 23: ...ACM 16AT switch activations The slave may condense several monitor points into one annunciator point to com municate with the NIB For example several intelligent smoke detectors could be assigned to a...

Page 24: ...gram point 2 in the master Normal operation of this feature indicates an alarm in the slave and that alarm is silenceable from the master If the alarm is silenced from the slave an open circuit condit...

Page 25: ...dresses may not be used for other MMX 1 or CMX 1 standard modules Output points that are to be silenced from the master should be programmed as signal type C blank Output points that are not to be si...

Page 26: ...of the two upper slots to permit easy access to NIB wir ing and switch settings Note that the NIB mechanically eliminates one LIB posi tion and in some instances could require the installation of an a...

Page 27: ...these additional EIA 485 devices Connect the LIB SLC loop from the master AM2020 AFP1010 to the NIB s SLC in put terminals Typically each NIB is connected to a single LIB in the master AM2020 AFP1010...

Page 28: ...DDRESS to START ADDRESS SIZE 1 inclusive Note that the total of START ADDRESS SIZE 1 must be 96 or less for the NIB to operate START ADDRESS SIZE 1 96 DIP Switch Settings Refer to Table 1 3 for the re...

Page 29: ...is used see note 8 5 Each AFP 200 slave uses eight points for AFP 200 system functions The re maining 88 NIB points can be used in multiples of eight to display the status of AFP zones 1 to 88 6 The...

Page 30: ...size range in dicates improper setting No alarm is reported at the first SLC loop address when an alarm is present in the slave within the switch selected NIB size range Alarm Bus Cable Installation...

Page 31: ...IA 485 NIB 96 NIB 96 NIB 96 NIB 96 AIM 200 Slave System 5000 CPU Slave System 500 CPU EIA 485 Notes 1 All external EIA 485 wiring is supervised and power limited 2 Connect main power harness daisy cha...

Page 32: ...xcept those restricted above defined by the NIB size switch NIB software P N 73454 or higher The NIB will detect an error if there is no communication for more than 60 seconds with one or more of the...

Page 33: ...ve control panels must be able to function as stand alone units dur ing loss of communications with the master control panel Therefore each slave panel must be programmed for complete local input outp...

Page 34: ...Document 15666 Rev D 9 19 96 34 Technical Manuals Online http www tech man com...

Page 35: ...Document 15666 Rev D 9 19 96 35 Technical Manuals Online http www tech man com...