TB-SRTG: Gas Floor Model Rethermalizer
OPERATION
L20-376, rev. 1 (08/18)
17
WARNING
Water must completely cover the heat
tubes at all times while appliance is on.
Dry fired heat tubes are extremely hot,
will shorten its service life and may
void your warranty.
Rethermalizer Digital Thermostat
2.3. APPLIANCE
START
UP
Refer to the following procedure to start the appliance prior to operation.
1. Ensure that the drain valve is closed.
2. Fill the cook tank with water. (See section 2.1 “Filling the Appliance”)
3. Light the appliance. (See section 1.9.2 “Lighting Instructions”)
4. Turn the ON/OFF (I/O) switch, to the ON (I) position.
5. The appliance’s controller may need to be turned on. Press the
*
button to turn the
controller on.
*
The specified button may appear slightly
different then shown. Refer to the operator’s
manual for your appliance’s specific control
type to determine the exact appearance of each
button and display.
6. The appliance is now on and heating the water
in the cook tank.
2.4. TEMPERATURE CONTROL PROGRAMMING
A jumper wire must be installed between ter5 and –3
on the back of the controller. Controller is non-programmable
without the wire installed.
2.4.1. PROGRAMMING SET TEMPERATURE
Press , display shows
“
SP1
”
(
Set Temperature mode – Set Temperature is
programmed using this function).
Press , display shows “
XXX
”, where XXX = current set temperature.
Press buttons to change the temperature setting.
(NOTE: If set temperature
will not adjust to desired setting, check the HI and LO temperature settings).
Press , to save the new temperature setting.
2.4.2. ADDITIONAL CONTROLLER FUNCTIONS
Some controllers have additional functions not described in this manual. If your appliance’s
controller has additional functions, refer to the controller’s operation manual to access these
functions.
WARNING
NEVER operate the appliance with an empty cook tank. It may void the warranty.
Adding water after the heat tubes have been heated may cause injuries from hot
splattering liquids and steam.