INSTALLATION
10
L20-376, rev. 1 (08/18)
ON
OFF
1.9. INITIAL
ADJUSTMENTS
After your appliance has been properly installed as described in the installation section of this
manual, it will need to be adjusted to ensure that it will perform as designed. A qualified person must
perform these adjustments.
To perform these adjustments the following tools will be needed:
• Manometer
• Digital Thermometer (Temperature Probe)
• DC Microammeter
1.9.1. FILLING THE APPLIANCE
Refer to the following procedure to fill the cook
tank prior to operation.
1. Ensure that the drain valve is closed. The
drain valve is a Push/Pull system, Pull Out
to open the drain, and Push all the way in to
close the drain.
2. This appliance is equipped with an automatic
water level maintaining system. To fill the
tank with water, turn the unit’s ON/OFF
switch to the ON position. This will cause
the tank to fill with water. The tank will
continue to fill until the water level reaches
the level sensors.
1.9.2. LIGHTING
INSTRUCTIONS
There is nothing to manually light on the electronic ignition system. Pilot ignition is performed and
controlled by the electronic ignition system. Refer to the following instructions to light the
appliance.
1. Open the gas supply valves to the appliance.
2. Turn the gas valve knob to the ON position.
3. If the appliance is equipped with a I/0 (ON/OFF) switch, turn it to
the I (ON) position.
4. If the appliance is equipped with a controller is may need to be turned on. Refer to the
operator’s manual for your appliance’s specific control type to determine how to do this.
5. When the water reaches the correct operating level, the main burners will light and be
controlled by the thermostat.
WARNING
Water must completely cover the heat tubes at all times while appliance is on.
CAUTION
This appliance is not designed for cooking with oil. Fill with potable water only.
WARNING
During operation there is an open flame inside this appliance. The unit may get hot enough to
set near by materials on fire. Keep the area around the appliance free from combustibles.
Push Ball Handle In
To Close The Drain