4 Other 

Displays:

 [PROBE OP] [OPEN]

Open probe detection is standard on all Pitco controls.  If probe is detected open, normal heating
and cooking activities are suspended.

 [HIGH TMP] [HIGH TMP]

This display warns operators that the vat temperature has exceeded set temperature by 40°F
(22°C), or an absolute maximum of 410°F (210°C).  This display does not show the status of the
mechanical high limit switch.

 [DRAINING] [TURN OFF]

This message indicates that the drain valve has been opened, the vat is assumed to be empty by
the controller.  Normal heat control activities are suspended.  To restore to normal operation,
close the drain value.  Display will show [TURN OFF] [TURN OFF].

Turn controller off, and refill the vat.  Continue with normal operations at section 1.

[HEAT] [FAILURE] OR [IGNITION] [FAILURE]

This message indicates that the heating system failed to respond.  Typically, the high
temperature limit switch has tripped and is in need of resetting.  In the case on gas fired
appliances, this message will display if the pilot fails to light or is detected marginal by the ignition
module.

 [SYSTEM] [FAILURE]

This message indicates a shorted probe. If probe is detected as a short circuit, normal heating
and cooking activities are suspended.

Summary of Contents for Solstice I12 60126801

Page 1: ...control developed for Pitco fryer products This microprocessor control offers the latest cooking technology including temperature and time compensation that requires no user adjustments for consistent...

Page 2: ...n 4 1 7 2 Manual Boil Entry 5 2 To Enter Programming Level 1 for the Store Manager 5 2 1 To Set Cook Temperature 5 2 2 To Change a Product Key Cook Shake Hold and Hold Pre Alarm Times 5 2 2 1 Cook Tim...

Page 3: ...eady to cook Press the desired product key and place product into the vat The indicator above the product key will flash to indicate the cook timer is running In the example above product 4 is cooking...

Page 4: ...return to READY 1 7 To perform a Boil Out operation Normal maintenance of a fryer requires regular tank cleaning This process involves draining the vat of oil and filling with water Cleaning solution...

Page 5: ...g the product keys as numeric keypad for entry Display still shows PROGRAM From the PROGRAM display continue with this section or go to section 3 2 1 To Set Cook Temperature Press the thermometer key...

Page 6: ...larm Hold Pre Alarm is a timer setting that is used to warn operators that the Hold Time is about to expire To use Hold Pre Alarm time value must be a non zero value and must be set to a value less th...

Page 7: ...PROGRAM If PASS REQ is selected display will show PASSnnnn NEW PASS to prompt for new password Displayed value nnnn is the current password Use the product keys for numeric entry to change password P...

Page 8: ...Press the product key 0 Display will show FnnnLyyy where nnn is the factory recovery value and yyy is the last warm up recovery value After recording these values press the P key Display returns to P...

Page 9: ...lve has been opened the vat is assumed to be empty by the controller Normal heat control activities are suspended To restore to normal operation close the drain value Display will show TURN OFF TURN O...

Page 10: ...Solstice I12 Cooking Computer Single Vat 60126801 and Dual Vat 60126802 L20 282 Rev 0 4 06 10 THIS PAGE LEFT INTENTIONALLY BLANK...

Page 11: ...Solstice I12 Cooking Computer Single Vat 60126801 and Dual Vat 60126802 L20 282 Rev 0 4 06 11 THIS PAGE LEFT INTENTIONALLY BLANK...

Page 12: ...nada only 603 225 6684 World Wide In the event of problems with or questions about your equipment please contact the Pitco Frialator Authorized Service and Parts representative ASAP covering your area...

Reviews: