Solstice I12 Cooking Computer Operations
Single Vat (60126801) and Dual Vat (60126802)
L20-282 Rev 0 (2/07)
2
Table of Contents
1 Key Locations and Functions: .....................................................................3
1.1
To turn the appliance ON:.................................................................................... 3
1.2
To turn the appliance OFF: .................................................................................. 3
1.3
To start a cook: .................................................................................................... 3
1.4
To cancel a cook:................................................................................................. 3
1.5
To check Actual and Set temperatures:............................................................... 3
1.6
To View Current Settings for cook, shake, and hold times: ................................. 4
1.7
To perform a Boil Out operation:.......................................................................... 4
1.7.1
Automatic Boil Entry (Water Detection): .....................................................................4
1.7.2
Manual Boil Entry:.......................................................................................................5
2 To Enter Programming Level 1 (for the Store Manager): ...........................5
2.1
To Set Cook Temperature: .................................................................................. 5
2.2
To Change a Product Key–Cook, Shake, Hold, and Hold Pre-Alarm Times: ...... 5
2.2.1
Cook Time...................................................................................................................5
2.2.2
Shake Time.................................................................................................................6
2.2.3
Hold Time....................................................................................................................6
2.2.4
Hold Pre-Alarm ...........................................................................................................6
2.3
To Exit Level 1 programming: .............................................................................. 6
3 To Enter Programming Level 2 (for the Store Manager): ...........................6
3.1
Fahrenheit or Celsius Display: ............................................................................. 7
3.2
Password Change or Required?.......................................................................... 7
3.3
Beeper Volume and Tone: ................................................................................... 7
3.4
Language Selection: ............................................................................................ 7
3.5
Melt Cycle Type: .................................................................................................. 8
3.6
Recovery Test Value:........................................................................................... 8
3.7
Control or Timer: (Left side of Dual or Single Vat) ............................................... 8
3.8
Control or Timer: (Right side of Dual Vat)............................................................ 8
4 Other Displays: ..............................................................................................9