Pitco Solstice I12 60126801 Operation Manual Download Page 5

Solstice I12 Cooking Computer Operations

Single Vat (60126801) and Dual Vat (60126802)

L20-282 Rev 0  (2/07)

5

1

2

2

0

0

1

Level 1 & 2 Password

6

8

6

4

1.7.2  Manual Boil Entry:

After filling an empty vat with water, turn the appliance on.  Press the
thermometer key and enter key sequence [2], [1], [2].  

If control is set

to display in the Celsius scale, press [1], [0], [0] keys to manually
enter boil mode.

  The display will show [  BOIL  ] to indicate entry into

boil mode.

To exit boil mode, control must be turned off.

To Enter Programming Level 1 (for the Store Manager):

Note: The factory default setting for this control does not require an operator password to

be entered.  However, the operator password requirement and value may be
changed in section 3.2.  This text assumes the operator password is disabled.  Entry
of a password when NOT required will not interfere with the programming process.

With no cook timers running, displays will show one of the following displays: [HEATING], [MELT]
[LIQUID (or SOLID)], or [READY].

Press the [P] program key.  Left display will show
[PROGRAM].  Right display will be blank.

Enter password 6684 using the product keys as numeric keypad for entry.

Display still shows [PROGRAM].

From the [PROGRAM] display, continue with this section or go to section 3.

2.1 

To Set Cook Temperature:

Press the thermometer key once for Single Vat (left side of Dual Vat) or press key twice
for Dual Vat (right side of Dual Vat).

The display will show [SET xxxF] [TEMP] or [SET xxxC] [TEMP], where “xxx” is the
temperature setting.  Use the product keys for numeric entry to adjust the current
setting.  Press the [P] key to save setting.  Display now shows [PROGRAM].  To exit
here, press [P] again, or continue.

2.2 

To Change a Product Key–Cook, Shake, Hold, and Hold Pre-Alarm Times:

For each product key, Cook, Shake, Hold, and Hold Pre-alarm times are set in this section.  With
display showing [PROGRAM], continue with the following section for each product key to change.

2.2.1 Cook 

Time

Cook Time may be set for each product key.  To deactivate any product key enter a zero
value for cook time.

Press the [Clock] key.  Display will show [SELECT] [PRODUCT].  Press the desired
product key to change.

The display is now showing [nCK mm:ss] [TIME] where “n” is the key number,
“CK” means Cook, and “mm:ss” is minutes and seconds.  Use the product
keys for numeric entry to adjust the current setting.  Press the [Clock] key to
save cook time and continue setup for this product key.

Summary of Contents for Solstice I12 60126801

Page 1: ...control developed for Pitco fryer products This microprocessor control offers the latest cooking technology including temperature and time compensation that requires no user adjustments for consistent...

Page 2: ...n 4 1 7 2 Manual Boil Entry 5 2 To Enter Programming Level 1 for the Store Manager 5 2 1 To Set Cook Temperature 5 2 2 To Change a Product Key Cook Shake Hold and Hold Pre Alarm Times 5 2 2 1 Cook Tim...

Page 3: ...eady to cook Press the desired product key and place product into the vat The indicator above the product key will flash to indicate the cook timer is running In the example above product 4 is cooking...

Page 4: ...return to READY 1 7 To perform a Boil Out operation Normal maintenance of a fryer requires regular tank cleaning This process involves draining the vat of oil and filling with water Cleaning solution...

Page 5: ...g the product keys as numeric keypad for entry Display still shows PROGRAM From the PROGRAM display continue with this section or go to section 3 2 1 To Set Cook Temperature Press the thermometer key...

Page 6: ...larm Hold Pre Alarm is a timer setting that is used to warn operators that the Hold Time is about to expire To use Hold Pre Alarm time value must be a non zero value and must be set to a value less th...

Page 7: ...PROGRAM If PASS REQ is selected display will show PASSnnnn NEW PASS to prompt for new password Displayed value nnnn is the current password Use the product keys for numeric entry to change password P...

Page 8: ...Press the product key 0 Display will show FnnnLyyy where nnn is the factory recovery value and yyy is the last warm up recovery value After recording these values press the P key Display returns to P...

Page 9: ...lve has been opened the vat is assumed to be empty by the controller Normal heat control activities are suspended To restore to normal operation close the drain value Display will show TURN OFF TURN O...

Page 10: ...Solstice I12 Cooking Computer Single Vat 60126801 and Dual Vat 60126802 L20 282 Rev 0 4 06 10 THIS PAGE LEFT INTENTIONALLY BLANK...

Page 11: ...Solstice I12 Cooking Computer Single Vat 60126801 and Dual Vat 60126802 L20 282 Rev 0 4 06 11 THIS PAGE LEFT INTENTIONALLY BLANK...

Page 12: ...nada only 603 225 6684 World Wide In the event of problems with or questions about your equipment please contact the Pitco Frialator Authorized Service and Parts representative ASAP covering your area...

Reviews: