SERVICE
32
L22-236 Rev. 2 (06/11)
13. Apply pipe thread compound or Teflon tape to
pipe threads of fitting. Slide probe wires
through fitting, (one at a time).
14. Tighten fitting into tank coupling, using 9/16”
wrench.
15. On split tanks, tighten ferrule nut, using 7/16”
wrench. Repeat steps 11 –15 for other tank
half.
16. Attach high limit bracket to burner bracket
using 5/16” hex bit. On split tanks the bracket
is installed on the lower center mounting holes
of the burner bracket. On full tanks, it is
mounted on the lower right two mounting
holes.
17. Straighten high limit capillary. Leave a slight
bend in capillary just below bulb.
18. Insert high limit bulb and capillary through
fitting in tank bottom. On split vats, ensure that
right-hand bulb is inserted into right-hand tank,
and left-hand bulb is inserted into left-hand
tank.
19. Apply pipe thread compound or Teflon tape to
pipe threads of high limit fitting, and tighten
fitting into tank coupling using 9/16” open-end
wrench.
20. Secure high limit bulb to tank tapping pad
using bulb clamp and Phillips screwdriver.
WARNING! SHUT OFF APPLIANCE AND DISCONNECT ALL POWER
CONNECTIONS PRIOR TO STARTING ANY SERVICE WORK