67
YPM-MG2196ZF
3 Elevation Detection
a)The elevation detection (slit count) is performed by
the photo interrupter.
b)After the elevation HOME switch is turned ON, the
photo interrupter counts the slits of the elevation
levers.
* The bottom position (the 1st stage) is detected when
the ELV HOME switch is turned on (not detected by
the photo interrupter).
2 Elevation
a)The Cam gear rotates to the elevation OK position.
b)The ELV motor rotates to slide the elevation lever via
the gears.
c)The 2 elevation levers (left and right) can synchronize
their sliding via the joint arm.
d)The shafts of the Stage Mech Assy engage with the
stair-like grooves in the elevation levers and the verti-
cal holes in the Main chassis via the rollers.
e) When the elevation levers slide, the Stage Mech Assy
moves up and down.
ELV motor
Photo interrupter
Elevation lever
ELV
HOME switch
joint arm
Elevation lever
Fig. 23
Summary of Contents for YPM-MG2196ZF
Page 3: ...3 YPM MG2196ZF ...
Page 4: ...4 YPM MG2196ZF 2 EXPLODED VIEWS AND PARTS LIST 2 1 CD MECHANISM ...
Page 17: ...17 YPM MG2196ZF ...
Page 19: ...19 1 2 3 4 1 2 3 4 D C B A SIDE B E E E E E E E E 16 1 5 8 9 A CD CORE UNIT A YPM MG2196ZF ...
Page 20: ...20 YPM MG2196ZF 1 2 3 4 1 2 3 4 D C B A CN801 PU UNIT A C D 4 2 SIDE PCB B SIDE PCB SIDE A B ...
Page 22: ...22 YPM MG2196ZF 1 2 3 4 1 2 3 4 D C B A D 4 4 MOTOR PCB B SPINDLE MOTOR M5 MOTOR PCB B D ...
Page 23: ...23 YPM MG2196ZF 1 2 3 4 1 2 3 4 D C B A D M M4 CARRIAGE 1 12 B CN864 ...
Page 28: ...28 YPM MG2196ZF 1 2 3 4 1 2 3 4 D C B A LOAD DOOR MODE E 4 9 FORDSW PCB I FORDSW PCB I SIDE A ...
Page 29: ...29 YPM MG2196ZF 5 6 7 8 5 6 7 8 D C B A I FORDSW PCB I SIDE B ...
Page 35: ...35 YPM MG2196ZF Grating waveform Ech Xch 20mV div AC Fch Ych 20mV div AC 45 0 75 60 30 90 ...