37
YPM-MG2196ZF
[SCAN REG-ON]
Power Off
TRK
MIN
SEC
[DISC3 F-CLS]
Focus Close/S-curve/
F, F0 Measurement
TRK
MIN
SEC
91
91
91
[DISC6 C/T]
Focus Mode Select
TRK
MIN
SEC
0X
0X
0X
[DISC1 T-CLS]
Tracking Servo
Close
TRK
MIN
SEC
00
00
00
[SCAN REG-ON]
Power ON
(T.OFFSET adjustment required)
TRK
MIN
SEC
00
00
00
[DISC3 F-CLS]
Power ON
(T.OFFSET adjustment not required)
TRK
MIN
SEC
99
99
99
[DISC1 T-CLS]
Mechanism Test Mode
Initial State
TRK
MIN
SEC
72
0*
**
[DISC6 C/T]
New Test Mode
[CD ON/OFF]
Source CD
TRK
MIN
SEC
** ** **
[SCAN REG-ON]
Power Off
[DISC1 T-CLS]
Tracking Close
(AGC, Applicable Servo)
TRK
MIN
SEC
XX
XX
XX
[DISC6 C/T]
Tracking Close
(No AGC, Applicable Servo)
TRK
MIN
SEC
XX
XX
XX
[DISC3 F-CLS]
Auto Adjustment Display
/Rough Servo
TRK
MIN
SEC
??
??
??
[DISC2 T-OPN]
Tracking Balance
Adjustment
TRK
MIN
SEC
8X
8X
8X
[Key]
Contents
Display
[TEST IN]
Test Mode In
[DISC3 F-CLS]
AGC
TRK
MIN
SEC
XX
XX
XX
[DISC6 C/T]
CRG/TR Jump Count
Select
TRK
MIN
SEC
XX
XX
XX
[TRK+ F-KICK]
CRG+/TR Jump+
TRK
MIN
SEC
XX
XX
XX
[TRK- R-KICK]
CRG–/TR Jump–
TRK
MIN
SEC
XX
XX
[DISC4 F-OPN]
SPINDLE
Uniform/
Double Switching
TRK
MIN
SEC
XX
XX
XX
[SCAN REG-ON]
Power Off
[DISC1 T-CLS]
AGC/F.BIAS
Display Switching
TRK
MIN
SEC
??
??
??
TRK
MIN
SEC
99
99
99
or
[TRK+ F-KICK]
CRG+
TRK
MIN
SEC
00
00
00
TRK
MIN
SEC
99
99
99
or
[TRK- R-KICK]
CRG-
TRK
MIN
SEC
00
00
00
TRK
MIN
SEC
99
99
99
or
[TRK+ F-KICK]
CRG+
TRK
MIN
SEC
8X
8X
8X
TRK
MIN
SEC
9X
9X
9X
or
[TRK- R-KICK]
CRG-
TRK
MIN
SEC
8X
8X
8X
TRK
MIN
SEC
9X
9X
9X
or
[SCAN REG-ON]
Power Off
[DISC2 T-OPN]
Trackig Open
TRK
MIN
SEC
8X
8X
8X
TRK
MIN
SEC
9X
9X
9X
or
[DISC2 T-OPN]
Trackig Open
TRK
MIN
SEC
8X
8X
8X
TRK
MIN
SEC
9X
9X
9X
or
*1
*6
*5
*3
*2
*2
*4
*1) Switching must take place in the following sequence.
TRK
MIN
SEC
00
00
00
TRK
(
)
MIN
SEC
99
99
99
S.Curve Check
TRK
MIN SEC
01
01
01
Focus EQ Measurement.
Focus Close
TRK
MIN SEC
02
02
02
*2)
→
→
→
→
→
9X(8X):91(81)
4 TR
92(82)
10 TR
93(83)
32 TR
94(84)
100 TR
95(85)
CRG Move
96(86)
Switching must take place in the following sequence.
*4)
→
→
→
F.AGC Gain
T.AGC Gain
F. BIAS Setting
(AGC Gain = (Current value/Initial value) x 20)
→
→
→
→
→
Single TR /4TR / 10TR / 32TR / 100TR
Single TR
*3) Switching must take place in the following sequence.
It applies to the CRG Move and 100TR Jump alone.
Min/Sec (or Track No.)
*5) Switching must take place in the following sequence.
F.Cancel Display
*6) Switching must take place in the following sequence.
T.Offset Display
T.Bal Display
Rough Servo.
(F.Bias value, F.Cancel value, T.Offset value, T.Bal value
= (Upper 8 bits of the setting (7F[H] to 80[H] + 128)/4
= 63[D] to 32[D] to 00[D]).
•
•
•
Operation of TR JUMPs other than 100TR is continued after your finger has left the key.
CRG Move and 100TR Jump are forced to the Tracking Close Mode when the key is released.
Powering on or off resets the Jump Mode to the Single TR (91).
When ending the test mode, apply the reset (the reset is applied in two minutes from powering off).
Note:
Note:
Note:
The commander for G1 mech. must be employed for controlling the test mode.
Sound is unavailable even after the tracking has been closed
(this trouble results when the IC for the STS is not controlled in the test mode).
When you pressed the [TRK+] or [TRK-] key during the Focus Search, you must turn the power off immediately
(otherwise, the lens can stick resulting in actuator damages).
[Key]
[SCAN REG-ON]
15 00H
[TRK+ F-KICK]
15 01H
[TRK- R-KICK]
15 02H
[DISC1 T-CLS]
15 03H
[DISC2 T-OPN]
15 04H
[DISC3 F-CLS]
15 05H
[DISC4 F-OPN]
15 06H
[DISC5 JMPOFF]
15 07H
[DISC6 C/T]
15 08H
Operation
Test Mode
New Test Mode
Power ON/OFF
CRG+/TR Jump+
(Toward outer perimeter)
Tracking Close/AGC gain,
F.Bias adjustment value display switching
Auto Tracking Balance adjustment/
Tracking Open
Focus Close, S.Curve, F.EQ measurement/
Rough Servo/AGC
Focus Open
Jump Off
Focus Mode select/Tracking Close/
CRG*TR Jump Switching
CRG-/TR Jump-
(Toward inner perimeter)
Error occurrence time/
Cause display switching
Track+/FF
Track-/REV
Mode
RAMDOM
Auto/Manual switching
ACC,BACKUP ON
TRK
MIN
SEC
FF
FF
FF
TRK
MIN
SEC
FF
FF
FF
TRK
MIN
SEC
FF
FF
FF
-
CD Player Flowchart
Summary of Contents for YPM-MG2196ZF
Page 3: ...3 YPM MG2196ZF ...
Page 4: ...4 YPM MG2196ZF 2 EXPLODED VIEWS AND PARTS LIST 2 1 CD MECHANISM ...
Page 17: ...17 YPM MG2196ZF ...
Page 19: ...19 1 2 3 4 1 2 3 4 D C B A SIDE B E E E E E E E E 16 1 5 8 9 A CD CORE UNIT A YPM MG2196ZF ...
Page 20: ...20 YPM MG2196ZF 1 2 3 4 1 2 3 4 D C B A CN801 PU UNIT A C D 4 2 SIDE PCB B SIDE PCB SIDE A B ...
Page 22: ...22 YPM MG2196ZF 1 2 3 4 1 2 3 4 D C B A D 4 4 MOTOR PCB B SPINDLE MOTOR M5 MOTOR PCB B D ...
Page 23: ...23 YPM MG2196ZF 1 2 3 4 1 2 3 4 D C B A D M M4 CARRIAGE 1 12 B CN864 ...
Page 28: ...28 YPM MG2196ZF 1 2 3 4 1 2 3 4 D C B A LOAD DOOR MODE E 4 9 FORDSW PCB I FORDSW PCB I SIDE A ...
Page 29: ...29 YPM MG2196ZF 5 6 7 8 5 6 7 8 D C B A I FORDSW PCB I SIDE B ...
Page 35: ...35 YPM MG2196ZF Grating waveform Ech Xch 20mV div AC Fch Ych 20mV div AC 45 0 75 60 30 90 ...