YPM-MG2196ZF
When the conditions mentioned above are satisfied and
focus is closed, the XSO terminal changes from "H" to
"L". Then, the microcomputer starts monitoring RFOK
signal through L.P.F after 40 ms.
If the system judges RFOK signal as "L", the microcom-
puter takes actions, including protection.
Fig. 10 shows operations related to focus closing. (The
illustration shows when the system cannot perform
focus closing.) S curve, search voltage, and actual lens
behavior can be checked by pressing the Focus Close
button when "01" is shown in Focus Mode Select in Test
mode.
REFOUT
FD
LENS POSITION
RELATIVE TO DISC
NEAR
FAR
"JUST FOCUSED"
SIN
REFOUT
Expanding around "Just Focused Point"
REFOUT
RFI
FOK
FEX
FZD
THRESHOLD
LEVEL
FZD
(INTERNAL SIGNAL)
Focus closing would normally take place at these points
XSO
(IN THE EVENT
FOCUS IS
CLOSED)
LEVEL
Fig. 10 Sequence of Focus Closing
Summary of Contents for YPM-MG2196ZF
Page 3: ...3 YPM MG2196ZF ...
Page 4: ...4 YPM MG2196ZF 2 EXPLODED VIEWS AND PARTS LIST 2 1 CD MECHANISM ...
Page 17: ...17 YPM MG2196ZF ...
Page 19: ...19 1 2 3 4 1 2 3 4 D C B A SIDE B E E E E E E E E 16 1 5 8 9 A CD CORE UNIT A YPM MG2196ZF ...
Page 20: ...20 YPM MG2196ZF 1 2 3 4 1 2 3 4 D C B A CN801 PU UNIT A C D 4 2 SIDE PCB B SIDE PCB SIDE A B ...
Page 22: ...22 YPM MG2196ZF 1 2 3 4 1 2 3 4 D C B A D 4 4 MOTOR PCB B SPINDLE MOTOR M5 MOTOR PCB B D ...
Page 23: ...23 YPM MG2196ZF 1 2 3 4 1 2 3 4 D C B A D M M4 CARRIAGE 1 12 B CN864 ...
Page 28: ...28 YPM MG2196ZF 1 2 3 4 1 2 3 4 D C B A LOAD DOOR MODE E 4 9 FORDSW PCB I FORDSW PCB I SIDE A ...
Page 29: ...29 YPM MG2196ZF 5 6 7 8 5 6 7 8 D C B A I FORDSW PCB I SIDE B ...
Page 35: ...35 YPM MG2196ZF Grating waveform Ech Xch 20mV div AC Fch Ych 20mV div AC 45 0 75 60 30 90 ...