37
EN
P
airing and
Calibr
ating
Calibration
This section describes calibrating (calibrating for the zero point for higher precision) while there is a load on the pedals and while
there is no load on the pedals.
It is necessary to calibrate the sensors on both the left and right sides. The right-side pedaling monitor sensor is used as an
example in this description. The procedure to calibrate the left side is the same as for the right side.
Calibrate the pedals under load within 5 minutes after calibrating a high accuracy zero point. Recalculate the high accuracy zero point
•
again if more than 5 minutes elapses.
Calibrating a Highly Precise Zero Point
1
Remove the left and right pedals from the crank arms.
2
Screw the calibration pedal bolt into the pedal hole on the right (R) side crank arm about 10 mm.
Screw it into the left (L) side to calibrate the left side.
•
“R” and “L” are engraved on the ends of the bolts for calibrating.
•
3
Hang the calibration weight onto the outer groove of the calibration pedal bolt.