PDP-6071PU
187
5
6
7
8
5
6
7
8
C
D
F
A
B
E
10. GENERAL INFORMATION
10.1 POWER ON SEQUENCE
1
: The remote control (or KEY) signal is input to the IF microcomputer.
2
: The IF microcomputer sends the operation data to the main microcomputer.
3
: The main microcomputer issues a startup command (PON) to the MOD microcomputer.
4
: The MOD microcomputer controls the relay of the power MOD of the PDP to startup the power of the PDP.
5
: The main microcomputer controls the ASIC power within the MTB to startup the power of the MTB.
MOD
Microcomputer
Power MOD
RELAY Control
BUFF
MTB
REM
BUFF
Q8303
IO
ASIC Power
Control
Power MOD
STB Control
REM
infrared
receiver
Side Keys
IF_UCOM
IC8301
MAIN_UCOM
IC8401
SR Jack
JA8810 (Elite only)
JA8811
4
1
2
5
3
1
KEY_AD2
KEY_AD1
TXD_MD
RXD_MD
REQ_MD
SR_IN
TXD_IF
RXD_IF
CE_IF
REQ_IF
BUSY_IF
CLK_IF
Summary of Contents for PDP-6070PU
Page 46: ...PDP 6071PU 46 1 2 3 4 1 2 3 4 C D F A B E 4 2 OVERALL CONNECTION DIAGRAM 2 2 ...
Page 52: ...PDP 6071PU 52 1 2 3 4 1 2 3 4 C D F A B E 4 6 60 X DRIVE ASSY 60 X DRIVE ASSY ...
Page 53: ...PDP 6071PU 53 5 6 7 8 5 6 7 8 C D F A B E from Power supply X Drive power supply map ...
Page 54: ...PDP 6071PU 54 1 2 3 4 1 2 3 4 C D F A B E 4 7 60 Y DRIVE ASSY 60 Y DRIVE ASSY ...
Page 205: ...PDP 6071PU 205 5 6 7 8 5 6 7 8 C D F A B E Block Diagram R2S11002AFT MAIN ASSY IC4701 AV SW ...