9.3.11 QMT
9.3.12 QNG
QMT :
Returning information of temperature and FAN speed.
0
Received Command Name
3 byte
‘QMT’ only
1
MTB Temperature
3 byte
3
Cjheck Sum
2 byte
2
MTB FAN Speed
1 byte
0: STOP
1:LOW
2:HIGH
Order Data
Size
Context
Format
Effective Condition
Function
Remarks
[QMT]
Every time
Output of status
MTB-side's temperature/FAN rotaing status
QNG :
Returning data (logs keep on Main microcomputer) on shutdown of Multi-Tuner Base.
0
Received Command Name on MTB
3 byte
‘QNG’ only
01
Latest NR data
1 byte
02
Data of subcategory for the latest NG
1 byte
03
Data of MTB hour meter for the latest NG
7 byte
04
Data of temperature for the latest NG
3 byte
05
2’st latest NG data
1 byte
06
Data of subcategory for the 2’st latest NG
1 byte
07
Data of MTB hourmeter for the 2’st latest NG
7 byte
08
Data of temperature for the 2’st latest NG
3 byte
:
:
:
09
3rd latest NG data
1 byte
10
Data of subcategory for the 3rd latest NG
1 byte
11
Data of MTB hourmeter for the 3rd latest NG
7 byte
12
Data of temperature for the 3rd latest NG
3 byte
29
8’st latest NG data
1 byte
30
Data of subcategory for the 7’st latest NG
1 byte
31
Data of MTB hour meter for the 7’st latest NG
7 byte
32
Data of temperature for the 7’st latest NG
3 byte
Details of Data and subcategory
0
Normal
1
failure of communication to Module microcomputer
MODULE (immediately Shutdown)
2
3-wire serial communication of Main microcomputer
Go to subcategory
⇒
No.1
3
IIC communication failure of Main microcomputer & Unknown error
Go to subcategory
⇒
No.2
4
communication failure of Main microcomputer
MAIN (immediately Power Supply OFF)
5
FAN stopped
FAN (immediately Power Supply OFF)
6
Abnormally high temperature at MTB.
failure of Digital Tuner
TEMP2 (After 30second warning, ture
Power Supply off)
7
Go to subcategory
⇒
No.3
8
failure of Power Supply
Go to subcategory
⇒
No.4
After 3 second warning, turn the Power
Supply OFF.
B
Speaker short-circuit
0
Non subcategory
1
IF microcomputer communication failure
IF (immediately Power Supply OFF)
2
MANTA communication failure (MULTI1)
MULTI1 (immediately Power Supply
OFF)
4
MANTA communication failure (I/P)
I/P
5
MANTA communication failure (D-SEL)
D-SEL
Order
Data
Size Context
<SD Information No.>
Data
Cause of shutdown
Remarks
<No.1 Subcategory Information on "failure in 3-wire serial communication of Main microcomputer">
Data
Cause of shutdown
Remarks
Format
Effective Condition
Function
Remarks
[QNG]
Every time
Output of status
Summary of Contents for PDP-6070PU
Page 46: ...PDP 6071PU 46 1 2 3 4 1 2 3 4 C D F A B E 4 2 OVERALL CONNECTION DIAGRAM 2 2 ...
Page 52: ...PDP 6071PU 52 1 2 3 4 1 2 3 4 C D F A B E 4 6 60 X DRIVE ASSY 60 X DRIVE ASSY ...
Page 53: ...PDP 6071PU 53 5 6 7 8 5 6 7 8 C D F A B E from Power supply X Drive power supply map ...
Page 54: ...PDP 6071PU 54 1 2 3 4 1 2 3 4 C D F A B E 4 7 60 Y DRIVE ASSY 60 Y DRIVE ASSY ...
Page 205: ...PDP 6071PU 205 5 6 7 8 5 6 7 8 C D F A B E Block Diagram R2S11002AFT MAIN ASSY IC4701 AV SW ...