PDP-6071PU
134
1
2
3
4
1
2
3
4
C
D
F
A
B
E
7.8
PROCEDURE WHEN REPLACING THE POWER SUPPLY UNIT
When replacing the Power Supply Unit, it is necessary to perform the following connector changes.
Otherwise the unit cannot work properly and the unit may be damaged.
Therefore perform these connector settings without fail when replacing the Power Supply Unit. ( before power on the unit)
u
1. As for service parts, the Jumper connector is
connected at connector P10.
2. Remove the jumper connector from connector
P10 and connect it to connector P11.
3. Connect the cable connector from power SW to P10.
Location of the jumper connector
Procedure of Changing Jumper Connector after replacing the Power Supply Unit
Summary of Contents for PDP-6070PU
Page 46: ...PDP 6071PU 46 1 2 3 4 1 2 3 4 C D F A B E 4 2 OVERALL CONNECTION DIAGRAM 2 2 ...
Page 52: ...PDP 6071PU 52 1 2 3 4 1 2 3 4 C D F A B E 4 6 60 X DRIVE ASSY 60 X DRIVE ASSY ...
Page 53: ...PDP 6071PU 53 5 6 7 8 5 6 7 8 C D F A B E from Power supply X Drive power supply map ...
Page 54: ...PDP 6071PU 54 1 2 3 4 1 2 3 4 C D F A B E 4 7 60 Y DRIVE ASSY 60 Y DRIVE ASSY ...
Page 205: ...PDP 6071PU 205 5 6 7 8 5 6 7 8 C D F A B E Block Diagram R2S11002AFT MAIN ASSY IC4701 AV SW ...