144
Menu Mode
10) Settings for peripheral equipment
This unit automatically identifies personal computer signals and video signals from DVD players etc. according to the
input signal frequency and is also equipped with a function that identifies the resolution of personal computer
signals. But when the signals a) and b) shown below are input, the signal identification function does not operate. In
such cases, the setting must be made manually.
1
Select SET UP.
Screen
1
2
Select SETTING and use the <
2
/
3
> button to
change the setting.
Each time the <
2
/
3
> button is pressed,
settings will change as follows.
a) 31.5kHz horizontal/60Hz vertical signal input
For INPUT 1 or INPUT 2:
For INPUT 5
★
(applies only when equipped
with PDA-5002):
VGA
WIDE VGA
b) 48.4kHz horizontal/60Hz vertical or
56.5kHz horizontal/70Hz vertical input signal
XGA
WIDE XGA
Set-able condition
: INPUT 1, 2 and 5
★
(Used only when the PDA-5002 is installed)
a) For 31.5kHz horizonal and 60Hz vertical signal input
b) For 48.4kHz horizontal and 60Hz vetical or 56.5kHz horizontal and 70Hz vertical signal input
Factory preset
: VGA, for “a”
XGA, for “b”
VGA
VIDEO
WIDE VGA
SELECT
ENTER
EXIT
SET
MENU
PICTURE
SET UP
OPTION
:
I N P UT
L
E
B
L A
:
V I D E O
: R G B
: A U T O
S E T T I N
V I DE O
S I GNA L
C L AM
OF F
AUT O
P
P O WER
G
: OF F
P
S I T I O N
O
: L OW
D I G I T A L
NR
: O F F
P URE C I N MA
E
H I GH C O T
N R A T
S
: O F F
MAIN MENU
INPUT1
I N P UT 1
SELECT
SET
EXIT
SET
MENU
S E T T I N G : V G A
SELECT
SET
EXIT
SET
MENU
S E T T I N G : X G A
1.
When the input signal is horizontally 31.5 kHz/vertically 60 Hz.
Input signal
Setting
Connected
Screen sizes that can be selected
devices
PDP-503CMX/503MXE PDP-433CMX/433MXE
525i (480i) SDTV
VIDEO
✭
VIDEO
WIDE/4:3/FULL/ZOOM
640 X 480
VGA
PC
DOT BY DOT/4:3/FULL
852 X 480
WVGA
PC
DOT BY DOT/FULL
2.
When the input signal is horizontally 48.4 kHz/vertically 60 Hz or horizontally 56.5 kHz/vertically 70 Hz
Input signal
Setting
Connected
Screen sizes that can be selected
devices
PDP-503CMX/503MXE PDP-433CMX/433MXE
1024 X 768
XGA
PC
DOT BY DOT/FULL
DOT BY DOT/4:3
1280 X 768
WXGA
PC
DOT BY DOT
FULL
★
(Used only when the PDA-5002 is installed)
Note:
The screen sizes that can be chosen and the display
method vary for each setting. To obtain the appropriate
reproduction method and screen size, confirm the
settings during the input of the corresponding signal
and change them as necessary.