PDP-5000EX
4
1
2
3
4
1
2
3
4
C
D
F
A
B
E
Fig.2 Charged Section and High Voltage Generating Point (Rear View)
Charged Section
The places where the commercial AC power is used without
passing through the power supply transformer.
If the places are touched, there is a risk of electric shock. In
addition, the measuring equipment can be damaged if it is
connected to the GND of the charged section and the GND of the
non-charged section while connecting the set directly to the
commercial AC power supply. Therefore, be sure to connect the
set via an insulated transformer and supply the current.
1. AC Power Cord
2. AC Inlet with Filter
3. Power Switch (S1)
4. Fuse (In the PANEL POWER SUPPLY Unit and MR POWER
SUPPLY Unit)
5. STB Transformer and Converter Transformer
(In the PANEL POWER SUPPLY Unit and MR POWER
SUPPLY Unit)
6. Other primary side of the PANEL POWER SUPPLY Unit and
MR POWER SUPPLY Unit
High Voltage Generating Point
The places where voltage is 100V or more except for the charged
places described above. If the places are touched, there is a risk of
electric shock.
I f t h e p r o c e d u r e s d e s c r i b e d i n “ 1 0 . 2 P O W E R O N / O F F
F U N C T I O N F O R T H E L A R G E - S I G N A L S Y S T E M ” a r e
performed before the power is turned off, the voltage will be
discharged in about 1 minutes.
1. POWER SUPPLY Unit................................................. (205 V)
2. 50FHD X DRIVE Assy ................................ (–180 V to 205 V)
3. 50 FHD Y DRIVE Assy ...................................(–60 V to 500 V)
4. 50FHD SCAN A Assy ....................................(–60 V to 500 V)
5. 50FHD SCAN B Assy ....................................(–60 V to 500 V)
: Part is the High Voltage Generating Points
other than the Charged Section.
: Part is Charged Section.
50FHD SCAN B Assy
Power Switch (S1)
50 FHD Y DRIVE Assy
50FHD X DRIVE Assy
AC Inlet
POWER SUPPLY Unit
50 FHD SCAN A Assy
50FHD SCAN A Assy
Summary of Contents for PDP-5000EX
Page 41: ...PDP 5000EX 41 5 6 7 8 5 6 7 8 C D F A B E ...
Page 43: ...PDP 5000EX 43 5 6 7 8 5 6 7 8 C D F A B E ...
Page 44: ...PDP 5000EX 44 1 2 3 4 1 2 3 4 C D F A B E 4 3 FHD MAIN ASSY FHD MAIN ASSY ...
Page 45: ...PDP 5000EX 45 5 6 7 8 5 6 7 8 C D F A B E ...
Page 46: ...PDP 5000EX 46 1 2 3 4 1 2 3 4 C D F A B E 4 4 50FHD X DRIVE ASSY 50FHD X DRIVE ASSY ...
Page 47: ...PDP 5000EX 47 5 6 7 8 5 6 7 8 C D F A B E from Power supply X Drive power supply map ...
Page 48: ...PDP 5000EX 48 1 2 3 4 1 2 3 4 C D F A B E 4 5 50FHD Y DRIVE ASSY 50FHD Y DRIVE ASSY ...
Page 51: ...PDP 5000EX 51 5 6 7 8 5 6 7 8 C D F A B E ...
Page 54: ...PDP 5000EX 54 1 2 3 4 1 2 3 4 C D F A B E 4 9 POWER SUPPLY UNIT POWER SUPPLY UNIT ...
Page 167: ...PDP 5000EX 167 5 6 7 8 5 6 7 8 C D F A B E 10 3 LED INFORMATION LED Pattern State LED Pattern ...