9.2 RS-232C COMMAND TABLE
If SR+ is set to ON, RS-232C commands cannot be received.
To switch the setting to RS-232C ON during Standby mode using the remote control unit, see 6.2 "RS-232C COMMANDS."
[Description of the items in the table]
1
Division: Classification of commands by definition
ADJ: Commands for adjustment
FNC: Commands for function setting
SGL: Commands for a single function
SUB: Auxiliary commands
2
Command Reception Point:
Classification by the microcomputer (main or module [Mod]) that receives a command to execute
3
Effective Commands during Factory Mode:
Classification of commands that are effective only in Factory mode (status after the command FAY is received)
The commands that are effective only in Factory mode return ERR during normal operation mode.
Command
Division
Function
command
Reception Point
Last
Memory
Only
FAY is
Effective
Remarks
Mod
Main
A
ABL
∗∗∗
ADJ
Adjusting the upper limit of the power
¶
Mod
¶
UP/DW key not effective
AMT
S00
FNC
Canceling audio muting
¶
S01
FNC
Executing audio muting
APW
S00
FNC
WB correction interlocked with APL: OFF
¶
¶
S01
FNC
WB correction interlocked with APL: ON
¶
¶
B
BCP
SGL
Copying the backup data in the EEPROM
¶
¶
BHI
∗∗∗
ADJ
User white balance : BLUE highlight
¶
¶
Main
BLW
∗∗∗
ADJ
User white balance : BLUE lowlight
¶
¶
Main
BRT
∗∗∗
ADJ
User brightness
¶
¶
Main
BSM
S00
FNC
After image/Burning safe mode: OFF
¶
S01
FNC
After image/Burning safe mode: ON
¶
C
CBU
SGL
Clearing backup data
¶
¶
CHM
SGL
Clearing data of the hour meter
¶
¶
CNT
∗∗∗
ADJ
User contrast
¶
¶
Main
CMT
SGL
Clearing data of the maximum temperature
¶
¶
CPC
SGL
Clearing power-on count data
¶
¶
CPD
SGL
Clearing power-down histrory
¶
¶
CPM
SGL
Clearing data of the pulse meter
¶
¶
CSD
SGL
Clearing shutdown history
¶
¶
D
DRV
S00
FNC
Main power off
¶
S01
FNC
Main power on
¶
DW*
SUB
To subtract
∗∗∗
to the adjustment value
(
∗∗∗
= 000 to 999, designated by a function command)
¶
E
ESV
S00
FNC
Setting Power Consumption mode to normal sequence and normal curve
¶
S01
FNC
Setting Power Consumption mode to silent sequence and normal curve
¶
S02
FNC
Setting Power Consumption mode to silent sequence and power-saving curve
¶
S10
FNC
Setting Power Consumption mode to normal sequence and normal curve
¶
S11
FNC
Setting Power Consumption mode to silent sequence and normal curve
¶
S12
FNC
Setting Power Consumption mode to silent sequence and power-saving curve
¶
Summary of Contents for PDP-5000EX
Page 41: ...PDP 5000EX 41 5 6 7 8 5 6 7 8 C D F A B E ...
Page 43: ...PDP 5000EX 43 5 6 7 8 5 6 7 8 C D F A B E ...
Page 44: ...PDP 5000EX 44 1 2 3 4 1 2 3 4 C D F A B E 4 3 FHD MAIN ASSY FHD MAIN ASSY ...
Page 45: ...PDP 5000EX 45 5 6 7 8 5 6 7 8 C D F A B E ...
Page 46: ...PDP 5000EX 46 1 2 3 4 1 2 3 4 C D F A B E 4 4 50FHD X DRIVE ASSY 50FHD X DRIVE ASSY ...
Page 47: ...PDP 5000EX 47 5 6 7 8 5 6 7 8 C D F A B E from Power supply X Drive power supply map ...
Page 48: ...PDP 5000EX 48 1 2 3 4 1 2 3 4 C D F A B E 4 5 50FHD Y DRIVE ASSY 50FHD Y DRIVE ASSY ...
Page 51: ...PDP 5000EX 51 5 6 7 8 5 6 7 8 C D F A B E ...
Page 54: ...PDP 5000EX 54 1 2 3 4 1 2 3 4 C D F A B E 4 9 POWER SUPPLY UNIT POWER SUPPLY UNIT ...
Page 167: ...PDP 5000EX 167 5 6 7 8 5 6 7 8 C D F A B E 10 3 LED INFORMATION LED Pattern State LED Pattern ...