9.3.11 QSI
14: Detection of existence of H
N
No H
Y
H detected
18 to 20: Each protection
operation status
0
Setting OFF
1
Setting ON (waiting)
2
Setting ON (during operation)
22: Transition of brightness by
protection operation
0
Upper limit state for brightness
1
Brightness being reduced
2
Lower limit state for brightness
3
Brightness being increased
Data Arrangement
Data
Length
Output Example
ECO
3 Byte
QSI
1
Type of drive sequence
3 Byte
60V
2
Standard/nonstandard
1 Byte
S
3
Type of ABL/WB tables
2 Byte
T1
4
Total value of PCN
4 Byte
0256
5
Total value of PRH
4 Byte
0256
6
Total value of PGH
4 Byte
0256
7
Total value of PBH
4 Byte
0256
8
Total value of PBR
4 Byte
0512
9
Total value of PRL
4 Byte
0512
10
Total value of PGL
4 Byte
0512
11
Total value of PBL
4 Byte
0512
12
Total value of ABL
3 Byte
128
13
Detection of V frequency
4 Byte
6002
14
Detection of existence of H
1 Byte
Y
15
Reserved
3 Byte
∗∗∗
16
Obtained APL data
4 Byte
1023
17
Number of SUS pulses
4 Byte
0457
18
Result of detection of still picture
1 Byte
1
19
Result of detection of cracking in the panel
1 Byte
1
20
Result of detection for scanning protection
1 Byte
1
21
Result of detection for external protection
1 Byte
1
22
Transition of protection operation
1 Byte
0
23
Reserved
4 Byte
∗∗∗∗
CS
2 Byte
27
• If data for an item cannot be obtained during Standby mode, the return data for that item will be "
∗
."
• The types of data for Items 1-3 in the table (drive sequence, standard/nonstandard, and type of ABL/WB tables) are the
same as with the command QPW.
• Each total value for Items 4-11 represents that of panel WB, user WB, and degradation correction, and the actual data being
sent to the ASTRA are output.
• Detection of V frequency: The V signal input to the panel is measured in the range of 30.51 to 99.99 Hz. The measured
value is multiplied by 100 and then output.
• Number of SUS pulses : The number is calculated from data from APL and the drive sequence. The output value must be
between 0174 and 2752.
• APL value: The APL value for the input video signal (or mask indication) will be output in the range of 0000 to 1023.
Command
Format
Effective Operation
Modes
Function
Remarks
[QSI]
All operations
To acquire all data on input video signals
Return data: 3 (ECO)+66(DATA)+2(CS)= 71 Byte
7
Acquisition of input signal data • • • [QSI]
The command QSI is for acquiring all data on input video signals.
Summary of Contents for PDP-5000EX
Page 41: ...PDP 5000EX 41 5 6 7 8 5 6 7 8 C D F A B E ...
Page 43: ...PDP 5000EX 43 5 6 7 8 5 6 7 8 C D F A B E ...
Page 44: ...PDP 5000EX 44 1 2 3 4 1 2 3 4 C D F A B E 4 3 FHD MAIN ASSY FHD MAIN ASSY ...
Page 45: ...PDP 5000EX 45 5 6 7 8 5 6 7 8 C D F A B E ...
Page 46: ...PDP 5000EX 46 1 2 3 4 1 2 3 4 C D F A B E 4 4 50FHD X DRIVE ASSY 50FHD X DRIVE ASSY ...
Page 47: ...PDP 5000EX 47 5 6 7 8 5 6 7 8 C D F A B E from Power supply X Drive power supply map ...
Page 48: ...PDP 5000EX 48 1 2 3 4 1 2 3 4 C D F A B E 4 5 50FHD Y DRIVE ASSY 50FHD Y DRIVE ASSY ...
Page 51: ...PDP 5000EX 51 5 6 7 8 5 6 7 8 C D F A B E ...
Page 54: ...PDP 5000EX 54 1 2 3 4 1 2 3 4 C D F A B E 4 9 POWER SUPPLY UNIT POWER SUPPLY UNIT ...
Page 167: ...PDP 5000EX 167 5 6 7 8 5 6 7 8 C D F A B E 10 3 LED INFORMATION LED Pattern State LED Pattern ...