PDP-506PE
55
5
6
7
8
5
6
7
8
C
D
F
A
B
E
¶
Detection of existence of H
N
No H
Y
H detected
¶
Transition of brightness by
protection operation
0
Upper limit state for brightness
1
Brightness being reduced
2
Lower limit state for brightness
3
Brightness being increased
Data Arrangement
Data
Length
Output Example
ECO
3Byte
QSI
1
Type of drive sequence
3byte
60V
2
Standard/nonstandard
1byte
S
3
Type of ABL/WB tables
2byte
T1
4
Total value of PCN
4byte
0256
5
Total value of PRH
4byte
0256
6
Total value of PGH
4byte
0256
7
Total value of PBH
4byte
0256
8
Total value of PBR
4byte
0512
9
Total value of PRL
4byte
0512
10
Total value of PGL
4byte
0512
11
Total value of PBL
4byte
0512
12
Reservation
2byte
∗∗
13
Detection of existence of H
1byte
Y
14
Detection of V frequency
4byte
6002
15
Reservation
4byte
∗∗∗∗
16
Obtained APL data
4byte
1023
17
Number of SUS pulses
4byte
0457
18
Result of detection of still picture
1byte
1
19
Result of detection of cracking in the panel
1byte
1
20
Result of detection for scanning protection
1byte
1
21
Result of detection for external protection
1byte
1
22
Transition of protection operation
1byte
0
23
Reservation
4byte
∗∗∗∗
CS
2Byte
27
• If data for an item cannot be obtained during Standby mode, the return data for that item will be "
∗
."
• The types of data for Items 1-3 in the table (drive sequence, standard/nonstandard, and type of ABL/WB tables) are the
same as with the command QPW.
• Each total value for Items 4-11 represents that of panel WB, user WB, and degradation correction, and the actual data being
sent to the ASTRA are output.
• Detection of V frequency: The V signal input to the panel is measured in the range of 30.51 to 99.99 Hz. The measured
value is multiplied by 100 and then output.
• Number of SUS pulses : The number is calculated from data from APL and the drive sequence. The output value must be
between 0174 and 2752.
• APL value: The APL value for the input video signal (or mask indication) will be output in the range of 0000 to 1023.
Command
Format
Effective Operation
Modes
Function
Remarks
[QSI]
All operations
To acquire all data on input video signals
Return data: 3 (ECO)+66(DATA)+2(CS)=71Byte
7
Acquisition of input signal data • • • [QSI]
The command QSI is for acquiring all data on input video signals.