![Pioneer PDP-436PU Service Manual Download Page 43](http://html.mh-extra.com/html/pioneer/pdp-436pu/pdp-436pu_service-manual_329979043.webp)
PDP-506PE
43
5
6
7
8
5
6
7
8
C
D
F
A
B
E
7
Error process
If an error is generated between STX and ETX, a return signal will not be issued.
• If the operation of a received command is not possible in a certain status, "XXX" (3 characters) will be sent back.
Example of communication: If an adjustment command that gives an adjustment value out of the adjustable range is sent
MR / External PC
Returns from the PDP
STX
0x02
ETX
0x03
ID
∗∗
Adjustment
Command
VOL
Adjustment
Value
128
STX
0x02
ETX
0x03
Command
XXX
7
Communication protocol
Start bit
: 1bit
Data
: 8bit
Parity
: 0 (none)
Stop bit
: 1bit
Baud rate
: 38400bps
7
Start and stop conditions
STX (start condition): 0x02
ETX (stop condition): 0x03
7
ID setting
No ID setting (corresponding to all ASCII codes)
7
Acknowledgement (ACK)
• Acknowledgement (ACK) will be sent back when the unit returns to Standby mode for the next command after the
process of the received command is finished.
• The return data will be a received command in capital letters, but without an ID.
2. Command format
Example of communication: For a command listed on the command list
MR / External PC
Returns from the PDP
STX
0x02
ETX
0x03
ID
∗∗
Command
CBU
STX
0x02
ETX
0x03
Command
CBU
• If a received command is not one listed on the command list, "ERR" (3 characters) will be sent back.
Example of communication: For a command that is not listed on the command list
MR / External PC
Returns from the PDP
STX
0x02
ETX
0x03
ID
∗∗
Command
AAA
STX
0x02
ETX
0x03
Command
ERR