Data Arrangement
Data
Length
Output
Example
ECO
3Byte
QPW
1
Drive sequence
3Byte
60V
2
Standard/nonstandard
1Byte
S
3
Type of ABL/WB tables
2Byte
T2
4
ABL adjustment value
3Byte
128
5
R-HIGH adjustment value
3Byte
256
6
G-HIGH adjustment value
3Byte
256
7
B-HIGH adjustment value
3Byte
256
13
Peripheral luminance correction
1Byte
0
14
Reservation
1Byte
∗
15
WB interlocked with APL
1Byte
0
16
Transition of protective operations
1Byte
0
17
Reservation
2Byte
∗∗
8
R-LOW adjustment value
3Byte
512
9
G-LOW adjustment value
3Byte
512
10
B-LOW adjustment value
3Byte
512
11
Gamma setting
1Byte
A
12
Streaking correction
1Byte
1
CS
2Byte
37
Data Arrangement
Data
Length
Output Example
ECO
3Byte
QPM
1
Pulse meter B 1
8Byte
00000000
2
Pulse meter B 2
8Byte
00000000
3
Pulse meter B 3
8Byte
00000000
4
Pulse meter B 4
8Byte
00000000
5
Pulse meter B 5
8Byte
00000000
CS
2Byte
E7
¶
Setting for Items 12 and 15
0
OFF
1
ON
¶
Peripheral luminance
correction
0
OFF
2
ON (interlocked with APL)
¶
Type of ABL/WB tables
Tn
n: 1 to 4
¶
Gamma setting
n
0 to F
¶
Transition of brightness by
protective operations
0
Upper limit state for brightness
1
Brightness being reduced
2
Lower limit state for brightness
3
Brightness being increased
• The output data on the accumulated number of pulses for each block are calculated in the following way: the high-order 4
bytes of the accumulated number of pulses for each block are converted into a decimal number, and the high-order 8
digits are transmitted. The unit of each block is M_pulse (mega).
¶
Drive sequence
48V Video48 Hz
50V Video50 Hz
60V Video60 Hz
72V Video72 Hz
75V Video75 Hz
60P PC60Hz
70P PC70Hz
¶
Standard/
nonstandard
S
Standard
N
Nonstandard
Command
Format
Effective Operation
Modes
Function
Remarks
[QPW]
All operations
To acquire data on operations of the panel Return data: 3 (ECO)+35(DATA)+2(CS)=40Byte
7
Acquisition of ABL/WB adjustment data • • • [QPW]
The command QPW is for acquiring data on the panel's factory-preset items whose memory tables are changed in
sequence.
Command
Format
Effective Operation
Modes
Function
Remarks
[QPM]
All operations
To acquire data on operations of the panel Return data: 3 (ECO)+40(DATA)+2(CS)=45Byte
7
Acquisition of parameters • • • [QPM]
The command QPM is for acquiring the accumulated number of pulses for each of 5 blocks from the EEPROM.