4. RS-232C command for module microcomputer
Command
Name
Function
Effective only in
Factory mode
Remarks
A
ABL
∗∗∗
ABL ADJUSTMENT
Adjusting the upper limit of the power
?
AMT
S00
AUDIO MUTE OFF
Turning off the audio muting
S01
AUDIO MUTE ON
Turning on the audio muting
APW
S00
APL WB FUNCTION:OFF
WB correction interlocked with APL: OFF
?
S01
APL WB FUNCTION:ON
WB correction interlocked with APL: ON
?
B
BAL
∗∗∗
BALANCE ADJUSTMENT
Audio balance adjustment
BAS
∗∗∗
BASS ADJUSTMENT
Audio bass adjustment
BCP
BACKUP COPY
Copying the backup data in the EEPROM
?
C
CBU
CLEAR BACKUP
Clearing backup data
?
CHM
CLEAR HOUR METER
Clearing data of the hour meter
?
Used only when the panel is replaced
CPC
CLEAR POWER ON COUNT
Clearing power-on count data
?
Used only when the power unit is replaced
CPD
CLEAR POWER DOWN
Clearing power-down information
?
Used only when the panel is replaced
CPM
CLEAR PLUSE METER
Clearing data of the pulse meter
?
Used only when the panel is replaced
CSD
CLEAR SHUT DOWN
Clearing shutdown information
?
Used only when the panel is replaced
D
DRV
S00
DRIVE OFF
Main power off
S01
DRIVE ON
Main power on
E
ESV
S00
POWER CONTROL NORMAL Setting Power Consumption mode to 4-split normal curve
S01
POWER CONTROL MODE1
Setting Power Consumption mode to 2-split normal curve
S02
POWER CONTROL MODE2
Setting Power Consumption mode to 2-split power-saving curve
S10
POWER CONTROL NORMAL Setting Power Consumption mode to 4-split normal curve (domestic)
S11
POWER CONTROL MODE1
Setting Power Consumption mode to 2-split normal curve (domestic)
S12
POWER CONTROL MODE2
Setting Power Consumption mode to 2-split power-saving curve (domestic)
F
FAJ
FINISH ADJUSTMENT
Determining the flag of the HD DIGITAL Assy adjustment in "adjustment is completed"
?
?
FAN
FACTRY NO
FAY
FACTRY YES
Entering Factory mode
Turning the mask setting off
FCS
S00
FOCUS OFF
Turning the FOCUS function off
S01
FOCUS ON
Turning the FOCUS function on
M
MKC
S00
MASK COMBINATION OFF
MASK off
S01
MASK COMBINATION 01
H ramp (slant 1) M
?
S02
MASK COMBINATION 02
H ramp (slant 4) M
?
S03
MASK COMBINATION 03
Slanting ramp M
?
S04
MASK COMBINATION 04
30 for aging
?
S05
MASK COMBINATION 05
05 for aging
?
S06
MASK COMBINATION 06
Erasing afterimage 1
?
S07
MASK COMBINATION 07
Erasing afterimage 2 (RGB: zigzag, V: reverse)
?
S08
MASK COMBINATION 08
White (change in luminance level)
?
S09
MASK COMBINATION 09
PEAK SEEK RASTER
?
MKS
S00
MASK SINGLE OFF
MASK OFF
S01
MASK SINGLE 1
H ramp (slant 1)
?
S02
MASK SINGLE 2
H ramp (slant 4)
?
S03
MASK SINGLE 3
V ramp (slant 1)
?
S04
MASK SINGLE 4
Slanting ramp
?