8.3 HOW TO CLEAR HISTORY DATA
Clearance of various logs after the Assys are replaced
Besides adjustment data, data on accumulated power-on time and logs on defective parts of the product are backed up.
Some of those data must be cleared after the Assys are replaced for service.
Clearance of those data can be performed in the ETC layer of the Factory menu or with RS232C commands.
Notes: •
As the pulse-meter count is used for each correction function, the log must be cleared when the panel is replaced.
•
After you clear the log, the unit must be turned off then back on again to reflect the cleared data for each correction
function. If any adjustment is required after clearing the log, be sure to turn the unit off then back on again before
adjustment.
(1) Clearance of logs, using the Factory menu
1
Turn on the power.
2
Enter the Panel Factory mode.
3
Clear the various logs, as shown in the figure below.
Note:
The following example shows how to clear the PD log (PD I
N
FO.). To clear other items, select each item you wish to
clear then perform the same procedures.
4
Turn off the power.
PA
N
EL I
N
FORMATIO
N
ETC. (+)
BACKUP DATA :
N
O OPRT
BACKUP DATA :
N
O OPRT
DIGITAL EEPROM :
N
O OPRT
PD I
N
FO. < = > :
N
O OPRT
PD I
N
FO. < = > : CLEAR
Key Down 7th
Key Down
SET
Right
SET (5 sec)
Key Down
Key Down
Item
Content
Panel
Clearing at the Replacement
Clearing method
POWER SUPPLY
Unit
Other parts
RS-232C
Commands
Hour-meter
Accumulated power-on time
Must be cleared
N
o need to be
cleared
N
o need to be
cleared
CHM
Pulse-meter
Accumulated number of pulses emitted
Must be cleared
(mandatory)
N
o need to be
cleared
N
o need to be
cleared
CPM
Shutdown history
of the panel
Causes and hour-meter values for the
last eight shutdowns (SD) of the Panel
Must be cleared
N
o need to be
cleared
N
o need to be
cleared
CSD
Power-down history
Causes and hour-meter values for the last
eight power-downs (PDs) of the Panel
Must be cleared
N
o need to be
cleared
N
o need to be
cleared
CPD
Power-on counter
Relay-on count
N
o need to be
cleared
Must be cleared
(mandatory)
N
o need to be
cleared
CPC
MAX TEMP
Historical max. temperature of the
panel
Must be cleared
Must be cleared
Must be cleared
CMT
Factory Menu
(ETC layer)
HR-MTR I
N
FO.
PM/B1-B5
SD I
N
FO.
PD I
N
FO.
P COU
N
T I
N
FO.
MAX TEMP.
(2) Using the RS-232C commands
1
Turn on the power.
2
Issue the FAY command.
3
Issue the Delete command for a log you wish to clear.
4
Turn off the power.
Summary of Contents for KURO KRP-500P
Page 12: ...12 KRP 500P 1 2 3 4 A B C D E F 1 2 3 4 Remote Control Unit for WYSIXK5 and WYS5 types ...
Page 13: ...13 KRP 500P 5 6 7 8 5 6 7 8 A B C D E F Remote Control Unit for LFT type ...
Page 14: ...14 KRP 500P 1 2 3 4 A B C D E F 1 2 3 4 Remote Control Unit for WA5 type ...
Page 19: ...19 KRP 500P 5 6 7 8 5 6 7 8 A B C D E F ...
Page 20: ...20 KRP 500P 1 2 3 4 A B C D E F 1 2 3 4 4 BLOCK DIAGRAM 4 1 OVERALL WIRING DIAGRAM 1 2 ...
Page 22: ...22 KRP 500P 1 2 3 4 A B C D E F 1 2 3 4 4 2 OVERALL WIRING DIAGRAM 2 2 ...
Page 23: ...23 KRP 500P 5 6 7 8 5 6 7 8 A B C D E F OVERALL DIAGRAM KRP 500P ...
Page 139: ...139 KRP 500P 5 6 7 8 5 6 7 8 A B C D E F ...
Page 156: ...156 KRP 500P 1 2 3 4 A B C D E F 1 2 3 4 9 9 PANEL CHASSIS SECTION ...