[4] Standalone Operation Mode
Standalone Operation mode is available with the KRP-600P and KRP-500P, by issuing the RS-232C command shown below.
After disconnecting the system cable, connect an RS-232C cable to the display unit to issue a command.
SYSS00: Standalone Operation mode
SYSS01: System Operation mode
BLUE
RED
STA
N
DBY
O
N
After 10 sec.
Turn on with the remote control unit.
(After about 7 sec.)
Straight cable (D-SUB, 9-pin)
PC for controlling (Connect to the D-SUB [9-pin]
connector of the display unit.)
Data transfer rate at Standalone
Operation mode: 9600 bps
Notes:
• To update the software for the display, disconnect the system cable, connect an RS-232C cable (straight), then perform
updating.
• During System Operation mode, most of the RS-232C commands are invalid.
• The setting data during Standalone Operation mode immediately before the display is turned off will be stored in memory.
After finishing operation in Standalone Operation mode, be sure to issue the SYSS01 command to return the display to
System Operation mode before reconnecting it to the MR. If the display is connected to the MR without returning it to
System Operation mode, the MR will automatically enter Standby mode soon after it is turned on, in which case no image
will be displayed even though the display is turned on.
•
N
o audio nor video signals are output if any display port cable other than the one for this display is connected to its system
cable port (terminal). The mask signal (output in response to a mask command) is the only video output available during
Standalone
Operation
mode.
• During normal System Operation mode (SYSS01) the display monitors the connection status with the MR.
If communication between the MR and the display cannot be established for any reason, such as disconnection of the
system cable or MR’s AC power being off, a system error warning will be indicated with the LED and on the mask screen
for about 10 seconds, after which the display will automatically shut itself off. (Even after power-off, flashing of the LED for
warning
continues.)
Summary of Contents for KURO KRP-500P
Page 12: ...12 KRP 500P 1 2 3 4 A B C D E F 1 2 3 4 Remote Control Unit for WYSIXK5 and WYS5 types ...
Page 13: ...13 KRP 500P 5 6 7 8 5 6 7 8 A B C D E F Remote Control Unit for LFT type ...
Page 14: ...14 KRP 500P 1 2 3 4 A B C D E F 1 2 3 4 Remote Control Unit for WA5 type ...
Page 19: ...19 KRP 500P 5 6 7 8 5 6 7 8 A B C D E F ...
Page 20: ...20 KRP 500P 1 2 3 4 A B C D E F 1 2 3 4 4 BLOCK DIAGRAM 4 1 OVERALL WIRING DIAGRAM 1 2 ...
Page 22: ...22 KRP 500P 1 2 3 4 A B C D E F 1 2 3 4 4 2 OVERALL WIRING DIAGRAM 2 2 ...
Page 23: ...23 KRP 500P 5 6 7 8 5 6 7 8 A B C D E F OVERALL DIAGRAM KRP 500P ...
Page 139: ...139 KRP 500P 5 6 7 8 5 6 7 8 A B C D E F ...
Page 156: ...156 KRP 500P 1 2 3 4 A B C D E F 1 2 3 4 9 9 PANEL CHASSIS SECTION ...