137
KRP-500P
5
6
7
8
5
6
7
8
A
B
C
D
E
F
DELAY ADJUSTMENT OF THE CONTROL SIGNAL (SUS-D)
1
Measure the pulse width of the SUS-D signal.
2
Check the pulse width of the SUS-D input signal (gate terminal of Q2111).
Adjust the variable control so that the pulse width of the SUS-D input signal (gate terminal of Q2111) becomes the
same pulse width
±
5 nsec as the SUS-D signal.
Note:
• For details on measuring points of waveform, see the figure below.
50 % of the crest value
50 % of the crest value
50 % of the crest value
50 % of the crest value
SUS-D pulse width: Tsus - Dg
Adjust so that "Tsus - Dg = Tsus - D
±
5 nsec," using the variable
control shown in the table below:
SUS-D signal
(input to the DRI
V
E Assy)
SUS-D signal
(input to the gate terminal of Q2111)
SUS-D pulse width
Tsus - D
SUS-D pulse width
Tsus - Dg
Assy
VR
Y DRI
V
E Assy
V
R2001
Summary of Contents for KURO KRP-500P
Page 12: ...12 KRP 500P 1 2 3 4 A B C D E F 1 2 3 4 Remote Control Unit for WYSIXK5 and WYS5 types ...
Page 13: ...13 KRP 500P 5 6 7 8 5 6 7 8 A B C D E F Remote Control Unit for LFT type ...
Page 14: ...14 KRP 500P 1 2 3 4 A B C D E F 1 2 3 4 Remote Control Unit for WA5 type ...
Page 19: ...19 KRP 500P 5 6 7 8 5 6 7 8 A B C D E F ...
Page 20: ...20 KRP 500P 1 2 3 4 A B C D E F 1 2 3 4 4 BLOCK DIAGRAM 4 1 OVERALL WIRING DIAGRAM 1 2 ...
Page 22: ...22 KRP 500P 1 2 3 4 A B C D E F 1 2 3 4 4 2 OVERALL WIRING DIAGRAM 2 2 ...
Page 23: ...23 KRP 500P 5 6 7 8 5 6 7 8 A B C D E F OVERALL DIAGRAM KRP 500P ...
Page 139: ...139 KRP 500P 5 6 7 8 5 6 7 8 A B C D E F ...
Page 156: ...156 KRP 500P 1 2 3 4 A B C D E F 1 2 3 4 9 9 PANEL CHASSIS SECTION ...