83
AVIC-W8400NEX/XNUC
5
6
7
8
5
6
7
8
A
B
C
D
E
F
(1)
(2)
(7)
(8)
(1)
To (2)
Tracking close state
FBAL coefficient (layer 0)
FBAL coefficient (layer 1)
Focus gain coefficient (layer 0)
Focus gain coefficient (layer 1)
Tracking gain coefficient (layer 0)
Tracking gain coefficient (layer 1)
AS normalization adjustment value (layer 0)
AS normalization adjustment value (layer 1)
Error rate
measurement
Error rate
Focus gain coefficient (layer 0)
Focus gain coefficient (layer 1)
Tracking gain coefficient (layer 0)
Tracking gain coefficient (layer 1)
AS normalization adjustment value (layer 0)
AS normalization adjustment value (layer 1)
T.OPEN
Power_OFF
RF level value
indication start
5000 0000
RF level is informed
every 500msec.
RF level value
indication end
(1)
(2)
(5)
(6)
(3),(4)
(7)
(8)
(1)-(4)
(3)
The higher 2 digits of the designated ID are the value showing the test state.
The lower 6 digits show the ID.
Example) If 300000 is desired to be designated as the ID, designated ID: 4A03 0000.
(5)
(5)
The number for designation of the track number shall be selected from the track numbers previously prepared.
Switch to cyclic by (3). Fix by (4).
For CD: Tracks 1, 4, 10, 11 and 32
For DVD: Tracks 1, 4, 10, 11, 32, 64 and 100
Change the method for ID address designation.
Designation of digit by command (1) and (2). UP/DOWN of numbers by command (3) and (4). Fix by command (5).
(8)
[Note] If an error occurs at Power_OFF, reset cannot be made. In such a case, it is necessary to turn the power off and start the test mode once again.
To (2)
Error rate
measurement
Playback speed
switching
Focus Jump
ID Search
T.Jump+/-
T.OPEN
Power_OFF
DVDX1.3 -
1.6CAV
CDX4CLV:
4x00 0000
4A00 0000
Jump+ : 4B00 0000
Jump- : 4C00 0000
ID
designation
ID display
Track number
designation
Track number
indication
Search
start
Jump
start
4000 0000
4x00 0000
Error display
Power_OFF
Error occurrence
Error occurrence at Power_OFF
Error display
Error rate
Focus gain coefficient (layer 0)
Focus gain coefficient (layer 1)
Tracking gain coefficient (layer 0)
Tracking gain coefficient (layer 1)
AS normalization adjustment value (layer 0)
AS normalization adjustment value (layer 1)
When L0 layer : 4x00 0000
When L1 layer : 4x00 0000
L0 layer DVD X CAV,CD X 2CLV
:4000 0000
L0 layer DVD X 1CLV,CD X 1CLV
:4200 0000
L1 layer DVD X CAV
:4100 0000
L1 layer DVD X 1CLV
:4300 0000
V
Change
V
L0 layer DVD X 1.3 - 1.6CAV, CD X 4CLV
:4000 0000
L0 layer DVD X 1CLV
:4200 0000
L1 layer DVD X 1.3 - 1.6CAV
:4100 0000
L1 layer DVD X 1CLV
:4300 0000