You can switch from CHECK MODE to CALIBRATION MODE by pressing [LOOP RELOOP/EXIT] button.
!
Calibration is performed in the following 4 steps.
1
While touching the center of "+" symbol in red on the top left, press [LOOP RELOOP/EXIT] button.
2
While touching the center of "+" symbol in red on the top right, press [LOOP RELOOP/EXIT] button.
3
While touching the center of "+" symbol in red on the bottom left, press [LOOP RELOOP/EXIT] button.
4
While touching the center of "+" symbol in red on the bottom right, press [LOOP RELOOP/EXIT] button.
(Note: If you press [LOOP RELOOP/EXIT] button without touching any place and end the calibration, the calibration
value is discarded. Touch operation operates in the state without the calibration.)
!
You can check the FAN operation.
!
[HOT CUE A] button: FAN rotates slowly.
!
[HOT CUE B] button: FAN rotates fast.
!
[HOT CUE C] button: FAN rotation become stop.
!
The current rotation status is displayed on the right side of "STATUS".
!
The rotation status is maintained even if the mode is switched.
!
Touch display
Refer to "6.2 JOG LCD CALIBRATION".
[Mode 6/10] JOG LCD CALIBRATION PAGE
[Mode 7/10] FAN OPERATION CHECK PAGE
[Operators]
[LOOP RELOOP/EXIT]
button
[LOOP RELOOP/EXIT]
button
[HOT CUE C]
button
[HOT CUE C]
button
[HOT CUE A]
button
[HOT CUE A]
button
[HOT CUE B]
button
[HOT CUE B]
button
[Refer to it for the following repairs]
!
Check the operation after replacing Fan motor
!
Check the operation after replacing MAIN Assy or FANB Assy