background image

NEVER LEAVE HEATER UNATTENDED WHILE BURNING 

OR WHILE CONNECTED TO A POWER SOURCE

© 2017, Pinnacle Climate Technologies, Inc. 

Kerosene Forced Air Heater User’s Manual 

Maintenance

Service:

DO NOT TAMPER WITH THE UNIT. HAVE 

A COMPETENT SERVICEMAN MAKE ANY 

NECESSARY ADJUSTMENT OR REPAIRS.
Use only original equipment parts. The use of alternate 

or third party components can cause unsafe operating 

conditions and will void your warranty.  
We suggest following a maintenance schedule as follows:

FUEL / FUEL TANK:

Flush tank every 200 hours of operation or as needed.  

DO NOT flush with water; use fresh K-1 kerosene only. 

AIR FILTERS:

The air intake filter should be replaced or washed with 

soap and water and dried thoroughly every 500 hours 

of operation or less depending on conditions. 

The output and lint filters should be replaced 

every 500 hours of operation or less depending on 

conditions. (See Figure 4)

NOTE: Use of diesel fuel may require additional 

maintenance
FAN BLADES:

Blades should be cleaned at least once per heating 

season, depending on conditions. Remove all 

accumulated dust and dirt with a damp cloth, taking 

care not to bend any of the fan blades. Be sure the 

blades are dry before re-starting the heater.

FUEL FILTER:

The fuel filter should be cleaned at least twice 

per heating season. Clean the filter by rinsing 

it in clean K-1 Kerosene. Contaminated fuel 

could make cleaning the fuel filter necessary 

immediately.

NOTE: To remove the filter from models 45 - 

75T-KFA turn filter 90º clockwise. To remove the 

filter from models 125T - 215T-KFA turn filter 90º 

counter-clockwise. See Figure 3.
THERMISTER PLACEMENT:

Ensure the thermister wire is in the proper place. 

The wire should be lying on the bottom shell inside 

the heater with the plastic end placed under the 

motor support/motor and away from fan blade.

ROTOR:

The rotor with carbon vanes should be evaluated 

every heating season. The rotor is behind the air 

filters. The vanes should be inspected for damage 

or wear. The rotor should be inspected for damage, 

chips, wear, cracks.

Check rotor gap: 

Remove the rear cover. 

Loosen the two pump ring screws. Lift the pump 

ring upwards. Insert a 0.1 mm feeler gauge and 

apply slight downward pressure, enough to offer 

resistance when attempting to remove gauge.

Hand-tighten the two pump ring screws. Re-install 

the End Pump Cover and the plastic End Filter 

Cover. Start the heater and adjust to the proper 

pump pressure.

Air Output Filter

Intake Filter

Lint Filter

End Filter

Figure 4

7

Never service 

heater while it is 

plugged in or hot!

WARNING

Figure 3

Fuel Filter
Fuel Line

Side Cover

Summary of Contents for Remington REM-135T-KFA-O

Page 1: ...to Ventilation on Page 5 FACTORY ID 001 Safety Information FIRE BURN INHALATION AND EXPLOSION HAZARD Keep combustibles such as building materials paper or cardboard a safe distance away from the heate...

Page 2: ...use for temporary heating of buildings under construction alteration or repair Direct fired means that all of the combustion products of the heater enter the heated space This appliance is rated at 98...

Page 3: ...ls away from this heater Minimum Clearance From Combustibles 45 190T KFA 215T KFA Top 4 ft 4 ft Sides 4 ft 4 ft Front 8 ft 10 ft ALWAYS locate heater on a stable and level surface If your heater is eq...

Page 4: ...Manual 3 Wiring Diagrams 45 KFA 75T 215T KFA Assembly Instructions What s In The Box Models 45 KFA 75T KFA Remove the heater and all packaging materials from the shipping carton Note Save the box and...

Page 5: ...lace heater on wheel support and line up holes on the fuel tank lip 5 Attach front handle with 2 long screws 50 mm and 2 nuts through the second hole from the front on both sides of the tank lip and w...

Page 6: ...R use kerosene that has been stored from one season to the next Kerosene deteriorates over time OLD KEROSENE WILL NOT BURN PROPERLY IN THIS HEATER NOTE Kerosene should only be stored in a blue contain...

Page 7: ...temperature display will indicate the following When the temperature is less than 0 F the display says LO When the temperature is more that 99 F the display says HI Between 0 F and 99 F the display s...

Page 8: ...starting the heater FUEL FILTER The fuel filter should be cleaned at least twice per heating season Clean the filter by rinsing it in clean K 1 Kerosene Contaminated fuel could make cleaning the fuel...

Page 9: ...ESSURE While heater is operating turn adjusting screw clockwise to increase counter clockwise to decrease pressure Correct pump pressure is as follows Model Number Pump Pressure 45 KFA 3 0 PSI 75T KFA...

Page 10: ...proper spacing with rotor 1 Fill tank with fresh kerosene 2 Adjust pump pressure 3 Clean replace spark plug 4 Clean replace fuel filter 5 Clean replace nozzle 6 Rinse fuel tank with clean fresh kerose...

Page 11: ...POWER SOURCE 2017 Pinnacle Climate Technologies Inc Kerosene Forced Air Heater User s Manual 10 14 11 13 8 12 9 30 26 3 16 2 4 6 1 7 22 24 17 18 19 21 30 20 15 41 33 35 36 29 28 5 32 31 25 27 38 37 3...

Page 12: ...21 0510 70 021 0520 70 021 0520 18 Pump Body 70 020 0101 70 020 0101 70 020 0101 70 020 0401 70 020 0401 19 Rotor Kit 70 022 0100 70 022 0100 70 022 0100 70 022 0200 70 022 0200 20 End Pump Cover 70 0...

Page 13: ...If Pinnacle Climate Technologies Inc finds the item to be in normal operating condition or not defective the item will be returned freight collect This Limited Warranty is in lieu of all other expres...

Page 14: ...1 Industrial Blvd 101 Sauk Rapids MN 56379 USA Toll Free 866 676 1989 Fax 320 251 2922 Web www remingtonheater com Email info pinnacleclimate com 2017 Pinnacle Climate Technologies Inc...

Reviews: